Ultra-High-Resolution Imaging of Rectal Cancer with Photon-Counting Detector Computed Tomography: An Exploratory Pilot Study on the Impact of Slice Thickness and Monoenergetic Reconstruction Level on Image Quality

Background/Objectives: To evaluate, in an exploratory pilot study, the influence of slice thickness and monoenergetic (ME) level on quantitative and qualitative image quality of ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) in rectal cancer (RC). Methods: This prospective pilot study enrolled 21 patients with suspected RC undergoing pre-treatment PCD-CT between July 2023 and February 2025. All underwent a QuantumPlus portal venous phase, whose 3 mm/60 keV reconstruction served as the standard reference, plus a separate pelvic UHR acquisition. Sixteen UHR reconstructions were generated (0.6–3 mm; 45–70 keV). Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and noise were analyzed using linear mixed-effects models. Three readers independently rated overall image quality, perceived noise, mesorectal fascia (MRF) sharpness and lesion conspicuity relative to the reference; ratings were analyzed using mixed model ordinal regression. The primary analysis was the within-UHR comparison of reconstruction settings; the comparison with the reference, which differed in contrast phase and acquisition parameters, was descriptive. Results: Nineteen patients (mean age 61.7 ± 10.7 years, 73.7% male) were included. CNR showed a significant slice thickness–ME level interaction (p < 0.001), ranging from 4.85 ± 2.43 (3 mm/45 keV) to 0.86 ± 1.04 (0.6 mm/70 keV). SNR increased and noise decreased with thicker slices, while both decreased with higher ME levels (all p < 0.001). ME level influenced all four qualitative parameters (all p < 0.001); slice thickness significantly affected overall quality and perceived noise (p < 0.001) but not MRF sharpness or lesion conspicuity (p ≥ 0.115). Overall quality was rated favorably in 82.9% at 70 keV versus 45.6% at 45 keV. Lesion conspicuity reached 71.9–86.0% favorable ratings, whereas perceived noise was consistently rated worse than the reference, and UHR SNR remained below the reference in all settings. In a descriptive pooled summary, 3 mm/60 keV (68.0%) and 2 mm/70 keV (66.2%) were rated favorably most often, with overlapping confidence intervals. Conclusions: Slice thickness and ME level markedly influence UHR PCD-CT image quality in RC. One candidate working reconstruction for future validation is 3 mm at 60 keV, with 2 mm at 70 keV as a plausible alternative. Because the reference differed in acquisition and contrast phase and no diagnostic endpoint was assessed, these results do not establish a diagnostic benefit of UHR PCD-CT.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-11-09
DOI
https://doi.org/10.3390/diagnostics16213697
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Ultra-High-Resolution Imaging of Rectal Cancer with Photon-Counting Detector Computed Tomography: An Exploratory Pilot Study on the Impact of Slice Thickness and Monoenergetic Reconstruction Level on Image Quality

Johannes Laengle, Florian Lindenlaub, Michael Weber, Dietmar Tamandl et al.
Diagnostics
Advanced X-ray and CT Imaging
article

Ultra-High-Resolution Imaging of Rectal Cancer with Photon-Counting Detector Computed Tomography: An Exploratory Pilot Study on the Impact of Slice Thickness and Monoenergetic Reconstruction Level on Image Quality

Johannes Laengle, Florian Lindenlaub, Michael Weber, Dietmar Tamandl, Andreas Strassl, Michael M. Bergmann, Michael A. Arnoldner, Ahmed Ba‐Ssalamah, Christian Wassipaul, Philipp D. Stelzer, Andrea Herold, Daniela Beitzke, Bence Nemeth, Theresa Dachs
article en

Abstract

Background/Objectives: To evaluate, in an exploratory pilot study, the influence of slice thickness and monoenergetic (ME) level on quantitative and qualitative image quality of ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) in rectal cancer (RC). Methods: This prospective pilot study enrolled 21 patients with suspected RC undergoing pre-treatment PCD-CT between July 2023 and February 2025. All underwent a QuantumPlus portal venous phase, whose 3 mm/60 keV reconstruction served as the standard reference, plus a separate pelvic UHR acquisition. Sixteen UHR reconstructions were generated (0.6–3 mm; 45–70 keV). Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and noise were analyzed using linear mixed-effects models. Three readers independently rated overall image quality, perceived noise, mesorectal fascia (MRF) sharpness and lesion conspicuity relative to the reference; ratings were analyzed using mixed model ordinal regression. The primary analysis was the within-UHR comparison of reconstruction settings; the comparison with the reference, which differed in contrast phase and acquisition parameters, was descriptive. Results: Nineteen patients (mean age 61.7 ± 10.7 years, 73.7% male) were included. CNR showed a significant slice thickness–ME level interaction (p < 0.001), ranging from 4.85 ± 2.43 (3 mm/45 keV) to 0.86 ± 1.04 (0.6 mm/70 keV). SNR increased and noise decreased with thicker slices, while both decreased with higher ME levels (all p < 0.001). ME level influenced all four qualitative parameters (all p < 0.001); slice thickness significantly affected overall quality and perceived noise (p < 0.001) but not MRF sharpness or lesion conspicuity (p ≥ 0.115). Overall quality was rated favorably in 82.9% at 70 keV versus 45.6% at 45 keV. Lesion conspicuity reached 71.9–86.0% favorable ratings, whereas perceived noise was consistently rated worse than the reference, and UHR SNR remained below the reference in all settings. In a descriptive pooled summary, 3 mm/60 keV (68.0%) and 2 mm/70 keV (66.2%) were rated favorably most often, with overlapping confidence intervals. Conclusions: Slice thickness and ME level markedly influence UHR PCD-CT image quality in RC. One candidate working reconstruction for future validation is 3 mm at 60 keV, with 2 mm at 70 keV as a plausible alternative. Because the reference differed in acquisition and contrast phase and no diagnostic endpoint was assessed, these results do not establish a diagnostic benefit of UHR PCD-CT.

DiagnosticsVol. 16(21)
Comprehensive Cancer Center Vienna (AT), Medical University of Vienna (AT)
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon