The effect of magnetic resonance image slice thickness and voxel geometry on digital dental implant planning: an in vitro study

Abstract Objectives To evaluate the effect of magnetic resonance imaging (MRI) slice thickness and voxel geometry on digital dental implant planning compared to cone-beam computed tomography (CBCT). Methods Edentulous phantoms were scanned using CBCT and two MRI protocols: anisotropic and isotropic. Two calibrated examiners digitally planned the position of four implants for each sample ( n = 8) per exam (CBCT, anisotropic and isotropic). Diagnostic accuracy was assessed using implant angular deviation and linear measurements. Image quality was evaluated using a questionnaire regarding visualization of anatomical structures. Cost-to-planning-time ratio was assessed by exam costs per minute of planning. The Friedman and Wilcoxon tests were used to evaluate differences in diagnostic accuracy, planning time, and cost-to-planning-time ratio. Image quality ratings on a 5-point scale were classified as non-valid (≤ 2) or valid (≥ 3) for clinical use. Reliability was assessed by percentage agreement, and differences were evaluated using the chi-square test. Results A total of 96 implants were planned, with 32 in each exam. No significant differences were observed between exams for angular deviation ( p > 0.197), linear measurements ( p > 0.305), image quality ( p > 0.132), or planning time ( p = 0.093). However, CBCT had lower cost-to-planning-time ratio than anisotropic and isotropic MRI ( p = 0.012), which did not differ from each other ( p = 1.000). Inter-examiner agreement on image quality for anisotropic and isotropic MRI varied widely, with lower ratings for the mandibular nerve canal. Conclusion No statistically significant differences were detected among the imaging protocols in diagnostic accuracy or image quality under the investigated in vitro conditions.

Authors

Publication Details

Journal
Oral and Maxillofacial Surgery
Published
2026-11-10
DOI
https://doi.org/10.1007/s10006-026-01662-1
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The effect of magnetic resonance image slice thickness and voxel geometry on digital dental implant planning: an in vitro study

Johannes Kleinheinz, Dalva Cruz Laganá, Hian Nivaldo Parize, Lauren Oliveira Lima Bohner et al.
Oral and Maxillofacial Surgery
Dental Radiography and Imaging
article

The effect of magnetic resonance image slice thickness and voxel geometry on digital dental implant planning: an in vitro study

Johannes Kleinheinz, Dalva Cruz Laganá, Hian Nivaldo Parize, Lauren Oliveira Lima Bohner, Newton Sesma, Norbert Meier, Fabio Munhoz, Carlos Cordeiro
article en

Abstract

Abstract Objectives To evaluate the effect of magnetic resonance imaging (MRI) slice thickness and voxel geometry on digital dental implant planning compared to cone-beam computed tomography (CBCT). Methods Edentulous phantoms were scanned using CBCT and two MRI protocols: anisotropic and isotropic. Two calibrated examiners digitally planned the position of four implants for each sample ( n = 8) per exam (CBCT, anisotropic and isotropic). Diagnostic accuracy was assessed using implant angular deviation and linear measurements. Image quality was evaluated using a questionnaire regarding visualization of anatomical structures. Cost-to-planning-time ratio was assessed by exam costs per minute of planning. The Friedman and Wilcoxon tests were used to evaluate differences in diagnostic accuracy, planning time, and cost-to-planning-time ratio. Image quality ratings on a 5-point scale were classified as non-valid (≤ 2) or valid (≥ 3) for clinical use. Reliability was assessed by percentage agreement, and differences were evaluated using the chi-square test. Results A total of 96 implants were planned, with 32 in each exam. No significant differences were observed between exams for angular deviation ( p > 0.197), linear measurements ( p > 0.305), image quality ( p > 0.132), or planning time ( p = 0.093). However, CBCT had lower cost-to-planning-time ratio than anisotropic and isotropic MRI ( p = 0.012), which did not differ from each other ( p = 1.000). Inter-examiner agreement on image quality for anisotropic and isotropic MRI varied widely, with lower ratings for the mandibular nerve canal. Conclusion No statistically significant differences were detected among the imaging protocols in diagnostic accuracy or image quality under the investigated in vitro conditions.

Oral and Maxillofacial SurgeryVol. 30(1)
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon