Comparison of computed tomography‐based tibial torsion measurement techniques reveals significant technique‐dependent differences

Abstract Purpose To compare commonly used computed tomography (CT)‐based tibial torsion measurement discrepancies and evaluate their intra‐ and interobserver agreement, as measurement discrepancies between techniques have not been systematically assessed. Methods CT scans from 20 adult patients were retrospectively analysed. Tibial torsion was calculated using two proximal reference axes (posterior tibial plateau tangent and tibial tuberosity axis) and four distal axes (transmalleolar, ankle joint, Jend and Waidelich). Three observers performed all measurements independently and repeated them after 8–12 weeks. Differences among techniques were assessed using repeated‐measures analysis of variance with Bonferroni correction. Reliability was evaluated using intraclass correlation coefficients (ICCs). Results All measurement techniques differed significantly ( p < 0.05). Mean tibial torsion was 34.1° (standard deviation [SD] 8.6°) for the transmalleolar axis, 31.2° (SD 8.8°) for the ankle joint axis, 44.2° (SD 9.8°) for the Jend axis and 34.9° (SD 9.0°) for the Waidelich axis. Segmental values revealed a mean supratuberositary torsion of 26° (SD 6.7°) and a mean infratuberositary torsion of 7.9° (SD 8.8°) for the transmalleolar axis, 5.1° (SD 8.9°) for the ankle joint axis, 18.1° (SD 10.4°) for the Jend axis and 8.8° (SD 9.1°) for the Waidelich axis. All techniques showed excellent intra‐ and interobserver reliability (ICC > 0.89). Conclusion Tibial torsion values depended strongly on the measurement technique used. Technique‐specific normative values are essential, and radiology reports should explicitly identify the technique applied. Clinicians must account for these systematic differences when interpreting torsion values and planning derotational osteotomies. Level of Evidence Level III, retrospective comparative study.

Authors

Institutions

Publication Details

Journal
Knee Surgery Sports Traumatology Arthroscopy
Published
2026-11-09
DOI
https://doi.org/10.1002/ksa.70672
Primary Topic
Lower Extremity Biomechanics and Pathologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparison of computed tomography‐based tibial torsion measurement techniques reveals significant technique‐dependent differences

Raul Mayr, Moritz Kummann, Richard Andreas Lindtner, Peter Kaiser et al.
Knee Surgery Sports Traumatology Arthroscopy
Lower Extremity Biomechanics and Pathologies
article

Comparison of computed tomography‐based tibial torsion measurement techniques reveals significant technique‐dependent differences

Raul Mayr, Moritz Kummann, Richard Andreas Lindtner, Peter Kaiser, Ulrich Juen, Marcis Benefelds
article en

Abstract

Abstract Purpose To compare commonly used computed tomography (CT)‐based tibial torsion measurement discrepancies and evaluate their intra‐ and interobserver agreement, as measurement discrepancies between techniques have not been systematically assessed. Methods CT scans from 20 adult patients were retrospectively analysed. Tibial torsion was calculated using two proximal reference axes (posterior tibial plateau tangent and tibial tuberosity axis) and four distal axes (transmalleolar, ankle joint, Jend and Waidelich). Three observers performed all measurements independently and repeated them after 8–12 weeks. Differences among techniques were assessed using repeated‐measures analysis of variance with Bonferroni correction. Reliability was evaluated using intraclass correlation coefficients (ICCs). Results All measurement techniques differed significantly ( p < 0.05). Mean tibial torsion was 34.1° (standard deviation [SD] 8.6°) for the transmalleolar axis, 31.2° (SD 8.8°) for the ankle joint axis, 44.2° (SD 9.8°) for the Jend axis and 34.9° (SD 9.0°) for the Waidelich axis. Segmental values revealed a mean supratuberositary torsion of 26° (SD 6.7°) and a mean infratuberositary torsion of 7.9° (SD 8.8°) for the transmalleolar axis, 5.1° (SD 8.9°) for the ankle joint axis, 18.1° (SD 10.4°) for the Jend axis and 8.8° (SD 9.1°) for the Waidelich axis. All techniques showed excellent intra‐ and interobserver reliability (ICC > 0.89). Conclusion Tibial torsion values depended strongly on the measurement technique used. Technique‐specific normative values are essential, and radiology reports should explicitly identify the technique applied. Clinicians must account for these systematic differences when interpreting torsion values and planning derotational osteotomies. Level of Evidence Level III, retrospective comparative study.

Knee Surgery Sports Traumatology Arthroscopy
Innsbruck Medical University (AT), Universität Innsbruck (AT)
Lower Extremity Biomechanics and Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon