Clinical and Laboratory Factors Associated with Exchange Transfusion in Neonates with Severe Hyperbilirubinaemia: A Retrospective Cohort Study

Background and Objectives: Exchange transfusion (ET) remains a critical intervention for severe neonatal hyperbilirubinaemia, yet laboratory associations with ET receipt require careful interpretation. We examined characteristics associated with ET and post-procedure laboratory changes. Materials and Methods: This retrospective tertiary-centre cohort included 98 neonates evaluated between January 2020 and December 2025 (65 received ET; 33 did not). A four-covariate logistic regression model assessed associations with ET receipt. Discrimination, bootstrap optimism, cross-validated calibration and an exploratory creatinine-containing model were examined. Results: Peak total serum bilirubin (TSB) was higher among ET recipients than non-recipients (33.69 ± 6.31 versus 26.19 ± 3.64 mg/dL; p < 0.001). In the primary model (n = 98), peak TSB was associated with ET receipt (adjusted odds ratio 1.31 per mg/dL, 95% confidence interval 1.16–1.48; p < 0.001). The apparent area under the receiver operating characteristic curve (AUC) was 0.860, decreasing to 0.837 after bootstrap optimism correction. An exploratory six-covariate model (n = 97) yielded an apparent AUC of 0.874 and an optimism-corrected AUC of 0.836. Creatinine showed an adjusted association (odds ratio 1.58 per 0.1 mg/dL, 95% confidence interval 1.07–2.32), but its incremental AUC was uncertain (difference 0.014, 95% confidence interval −0.022 to 0.053). Following ET, bilirubin, platelet count and total calcium decreased. Conclusions: Peak TSB strongly distinguished infants who received ET, but this association partly reflects the bilirubin-based indication for treatment. Creatinine did not demonstrate a reliable incremental discrimination benefit. These findings reinforce guideline-based ET assessment and post-exchange monitoring, not the adoption of new treatment thresholds or prediction tools.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-11-09
DOI
https://doi.org/10.3390/jcm15218762
Primary Topic
Neonatal Health and Biochemistry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Clinical and Laboratory Factors Associated with Exchange Transfusion in Neonates with Severe Hyperbilirubinaemia: A Retrospective Cohort Study

Selçuk Yazıcı, Aslıhan İZOL, Sümeyya ERCAN
Journal of Clinical Medicine
Neonatal Health and Biochemistry
article

Clinical and Laboratory Factors Associated with Exchange Transfusion in Neonates with Severe Hyperbilirubinaemia: A Retrospective Cohort Study

Selçuk Yazıcı, Aslıhan İZOL, Sümeyya ERCAN
article en

Abstract

Background and Objectives: Exchange transfusion (ET) remains a critical intervention for severe neonatal hyperbilirubinaemia, yet laboratory associations with ET receipt require careful interpretation. We examined characteristics associated with ET and post-procedure laboratory changes. Materials and Methods: This retrospective tertiary-centre cohort included 98 neonates evaluated between January 2020 and December 2025 (65 received ET; 33 did not). A four-covariate logistic regression model assessed associations with ET receipt. Discrimination, bootstrap optimism, cross-validated calibration and an exploratory creatinine-containing model were examined. Results: Peak total serum bilirubin (TSB) was higher among ET recipients than non-recipients (33.69 ± 6.31 versus 26.19 ± 3.64 mg/dL; p < 0.001). In the primary model (n = 98), peak TSB was associated with ET receipt (adjusted odds ratio 1.31 per mg/dL, 95% confidence interval 1.16–1.48; p < 0.001). The apparent area under the receiver operating characteristic curve (AUC) was 0.860, decreasing to 0.837 after bootstrap optimism correction. An exploratory six-covariate model (n = 97) yielded an apparent AUC of 0.874 and an optimism-corrected AUC of 0.836. Creatinine showed an adjusted association (odds ratio 1.58 per 0.1 mg/dL, 95% confidence interval 1.07–2.32), but its incremental AUC was uncertain (difference 0.014, 95% confidence interval −0.022 to 0.053). Following ET, bilirubin, platelet count and total calcium decreased. Conclusions: Peak TSB strongly distinguished infants who received ET, but this association partly reflects the bilirubin-based indication for treatment. Creatinine did not demonstrate a reliable incremental discrimination benefit. These findings reinforce guideline-based ET assessment and post-exchange monitoring, not the adoption of new treatment thresholds or prediction tools.

Journal of Clinical MedicineVol. 15(21)
Şanlıurfa Mehmet Akif İnan Eğitim ve Araştırma Hastanesi (TR)
Neonatal Health and Biochemistry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon