Simplified Calibration and Laser Nonlinearity Error Analysis for Peak-Locking TDLAS Systems

Tunable diode laser absorption spectroscopy (TDLAS) has been widely applied in industrial gas detection, but traditional calibration methods face challenges including high standard gas consumption, exorbitant costs, and heavy calibration workloads—particularly under wide temperature and pressure ranges, where variations in laser parameters can introduce significant errors. This study proposes a simplified calibration method for peak-locking TDLAS systems based on wavelength modulation spectroscopy (WMS). First, a coupling relationship model between the modulation index (m) and amplitude modulation (AM) is established, and an iterative calibration method is developed to synchronously adjust the laser operating current and temperature, enabling both m = 2.2 and AM = 0.1 to converge to their target values simultaneously, thereby eliminating the need for per-device temperature–pressure–concentration ternary calibration. Subsequently, the effects of quadratic nonlinearity in the laser power–current (P-I) and wavenumber–current (v-I) curves on detection accuracy are systematically analyzed for both 2f/1f and 4f/1f WMS representation methods. The simulation results obtained within a temperature range of 300 K ± 100 K and a pressure range of 1 atm ± 0.2 atm show that, for 2f/1f-WMS, a v-I nonlinearity rate of ±5% yields a maximum detection error of no more than 0.11% (with the error peak occurring in the 40–65% concentration range and no zero offset), while a P-I nonlinearity rate of ±5% results in a maximum error of no more than 0.82%, nearly independent of concentration. By comparison, the 4f/1f-WMS scheme effectively suppresses the zero offset induced by P-I nonlinearity, achieves lower detection errors, and requires only span calibration for each device. The proposed method significantly reduces the calibration workload and cost of TDLAS systems while ensuring detection accuracy.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2026-11-09
DOI
https://doi.org/10.3390/photonics13111055
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Simplified Calibration and Laser Nonlinearity Error Analysis for Peak-Locking TDLAS Systems

余兆安 Yu Zhaoan, Tao Liu, Tieliang Lv, Kaiping Yuan
Photonics
Spectroscopy and Laser Applications
article

Simplified Calibration and Laser Nonlinearity Error Analysis for Peak-Locking TDLAS Systems

余兆安 Yu Zhaoan, Tao Liu, Tieliang Lv, Kaiping Yuan
article en

Abstract

Tunable diode laser absorption spectroscopy (TDLAS) has been widely applied in industrial gas detection, but traditional calibration methods face challenges including high standard gas consumption, exorbitant costs, and heavy calibration workloads—particularly under wide temperature and pressure ranges, where variations in laser parameters can introduce significant errors. This study proposes a simplified calibration method for peak-locking TDLAS systems based on wavelength modulation spectroscopy (WMS). First, a coupling relationship model between the modulation index (m) and amplitude modulation (AM) is established, and an iterative calibration method is developed to synchronously adjust the laser operating current and temperature, enabling both m = 2.2 and AM = 0.1 to converge to their target values simultaneously, thereby eliminating the need for per-device temperature–pressure–concentration ternary calibration. Subsequently, the effects of quadratic nonlinearity in the laser power–current (P-I) and wavenumber–current (v-I) curves on detection accuracy are systematically analyzed for both 2f/1f and 4f/1f WMS representation methods. The simulation results obtained within a temperature range of 300 K ± 100 K and a pressure range of 1 atm ± 0.2 atm show that, for 2f/1f-WMS, a v-I nonlinearity rate of ±5% yields a maximum detection error of no more than 0.11% (with the error peak occurring in the 40–65% concentration range and no zero offset), while a P-I nonlinearity rate of ±5% results in a maximum error of no more than 0.82%, nearly independent of concentration. By comparison, the 4f/1f-WMS scheme effectively suppresses the zero offset induced by P-I nonlinearity, achieves lower detection errors, and requires only span calibration for each device. The proposed method significantly reduces the calibration workload and cost of TDLAS systems while ensuring detection accuracy.

PhotonicsVol. 13(11)
Chinese Academy of Sciences (CN), Fudan University (CN), Institute of Microelectronics (CN)
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon