Agreement and Repeatability of Three Fractional Exhaled Nitric Oxide Analyzers in Patients with Chronic Obstructive Pulmonary Disease: A Prospective Comparative Study

Background and aim: Fractional exhaled nitric oxide (FeNO) is a non-invasive biomarker of airway inflammation that may provide complementary information on inflammatory phenotypes in chronic obstructive pulmonary disease (COPD). The increasing availability of portable FeNO analyzers requires assessment of their reproducibility and agreement before measurements obtained with different devices can be considered interchangeable. In this study, we aimed to compare the performance of three FeNO analyzers in patients with COPD. Methods: In this prospective study, consecutive patients with COPD underwent FeNO assessment using three analyzers: Medisoft Hyp’Air FeNO, Sunvou CA2122, and Sunvou TM2120. Two consecutive valid measurements were obtained with each device. Both within-device repeatability and between-device agreement were evaluated, while the number of measurement attempts recorded for each analyzer was investigated as an exploratory analysis of feasibility. Results: In total, 56 participants (69.6% male), with a mean age of 70.8 ± 4.3 years and a mean FEV1 of 42.3 ± 13.1% predicted, were enrolled. All analyzers showed excellent within-device repeatability, with ICCs of 0.976 for Hyp’Air, 0.967 for CA2122, and 0.992 for TM2120. Between-device absolute agreement was highest for Hyp’Air versus TM2120 (ICC 0.989), followed by CA2122 versus TM2120 (ICC 0.943) and Hyp’Air versus CA2122 (ICC 0.931). The median number of attempts was 4.5 [3.8–5.0] with Hyp’Air, 3.0 [2.0–3.0] with CA2122, and 2.0 [2.0–3.0] with TM2120 (overall p < 0.001). Conclusions: All three FeNO analyzers demonstrated excellent within-device repeatability in patients with COPD. TM2120 showed closer agreement with Hyp’Air than CA2122, although the limited representation of elevated FeNO values prevents firm conclusions regarding inter-device agreement at higher concentrations.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-11-09
DOI
https://doi.org/10.3390/jcm15218744
Primary Topic
Chronic Obstructive Pulmonary Disease (COPD) Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Agreement and Repeatability of Three Fractional Exhaled Nitric Oxide Analyzers in Patients with Chronic Obstructive Pulmonary Disease: A Prospective Comparative Study

Claudio Candia, Claudia Merola, Silvestro Ennio D’Anna, Antonio Iovine et al.
Journal of Clinical Medicine
Chronic Obstructive Pulmonary Disease (COPD) Research
article

Agreement and Repeatability of Three Fractional Exhaled Nitric Oxide Analyzers in Patients with Chronic Obstructive Pulmonary Disease: A Prospective Comparative Study

Claudio Candia, Claudia Merola, Silvestro Ennio D’Anna, Antonio Iovine, Mauro Maniscalco, Carmen Lombardi
article en

Abstract

Background and aim: Fractional exhaled nitric oxide (FeNO) is a non-invasive biomarker of airway inflammation that may provide complementary information on inflammatory phenotypes in chronic obstructive pulmonary disease (COPD). The increasing availability of portable FeNO analyzers requires assessment of their reproducibility and agreement before measurements obtained with different devices can be considered interchangeable. In this study, we aimed to compare the performance of three FeNO analyzers in patients with COPD. Methods: In this prospective study, consecutive patients with COPD underwent FeNO assessment using three analyzers: Medisoft Hyp’Air FeNO, Sunvou CA2122, and Sunvou TM2120. Two consecutive valid measurements were obtained with each device. Both within-device repeatability and between-device agreement were evaluated, while the number of measurement attempts recorded for each analyzer was investigated as an exploratory analysis of feasibility. Results: In total, 56 participants (69.6% male), with a mean age of 70.8 ± 4.3 years and a mean FEV1 of 42.3 ± 13.1% predicted, were enrolled. All analyzers showed excellent within-device repeatability, with ICCs of 0.976 for Hyp’Air, 0.967 for CA2122, and 0.992 for TM2120. Between-device absolute agreement was highest for Hyp’Air versus TM2120 (ICC 0.989), followed by CA2122 versus TM2120 (ICC 0.943) and Hyp’Air versus CA2122 (ICC 0.931). The median number of attempts was 4.5 [3.8–5.0] with Hyp’Air, 3.0 [2.0–3.0] with CA2122, and 2.0 [2.0–3.0] with TM2120 (overall p < 0.001). Conclusions: All three FeNO analyzers demonstrated excellent within-device repeatability in patients with COPD. TM2120 showed closer agreement with Hyp’Air than CA2122, although the limited representation of elevated FeNO values prevents firm conclusions regarding inter-device agreement at higher concentrations.

Journal of Clinical MedicineVol. 15(21)
Istituti Clinici Scientifici Maugeri (IT), University of Naples Federico II (IT)
Chronic Obstructive Pulmonary Disease (COPD) Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon