Agile manufacturing of PDMS microfluidic devices for cell culture without a clean room

Microfluidic devices control fluid flow and the cellular microenvironment, and their fabrication usually relies on photolithography in a clean room. For devices with features of hundreds of micrometers to millimeters, this route is slow and costly, especially during prototyping, when the design changes after each test. Here, we describe and benchmark a workflow to fabricate polydimethylsiloxane (PDMS) devices from laser-cut master molds, with equipment accessible to most biology laboratories. We cut three inexpensive materials, poly(methyl methacrylate) (PMMA), polystyrene and polyvinyl chloride (PVC) tape, over a grid of laser power and speed and measured each cut by scanning electron microscopy. Cut depth and width increased line-arly with the laser energy delivered per unit length, which gives a simple rule to choose the settings for each material. We then bonded the PDMS replicas to glass without a plasma cleaner, by stopping curing early, once the replica could be demolded, and completing it in contact with the glass. Without any surface treatment, these devices held up to about 400 mbar; activating the glass with a handheld corona device raised this to about 900 mbar, enough for perfusion. The master material set the surface of the device: PMMA gave smooth replicas, whereas PVC tape gave rough walls. A three-channel device molded on PMMA held two cell-laden gels in place with phase guides and supported the co-culture of cancer cells and fibroblasts under perfusion. Further analysis of flow laminarity and different mixer designs confirmed the robustness of this method. This workflow takes a digital design to a working de-vice within a day and lets biology laboratories adapt microfluidic devices to their experiments without the need of a clean room.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-11-09
DOI
https://doi.org/10.64898/2026.11.07.765050
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Agile manufacturing of PDMS microfluidic devices for cell culture without a clean room

Cristian Angeli, Juan Manuel GARCIA ARCOS, Jean-Abel Merino
bioRxiv (Cold Spring Harbor Laboratory)
Microfluidic and Capillary Electrophoresis Applications
preprint

Agile manufacturing of PDMS microfluidic devices for cell culture without a clean room

Cristian Angeli, Juan Manuel GARCIA ARCOS, Jean-Abel Merino
preprint en

Abstract

Microfluidic devices control fluid flow and the cellular microenvironment, and their fabrication usually relies on photolithography in a clean room. For devices with features of hundreds of micrometers to millimeters, this route is slow and costly, especially during prototyping, when the design changes after each test. Here, we describe and benchmark a workflow to fabricate polydimethylsiloxane (PDMS) devices from laser-cut master molds, with equipment accessible to most biology laboratories. We cut three inexpensive materials, poly(methyl methacrylate) (PMMA), polystyrene and polyvinyl chloride (PVC) tape, over a grid of laser power and speed and measured each cut by scanning electron microscopy. Cut depth and width increased line-arly with the laser energy delivered per unit length, which gives a simple rule to choose the settings for each material. We then bonded the PDMS replicas to glass without a plasma cleaner, by stopping curing early, once the replica could be demolded, and completing it in contact with the glass. Without any surface treatment, these devices held up to about 400 mbar; activating the glass with a handheld corona device raised this to about 900 mbar, enough for perfusion. The master material set the surface of the device: PMMA gave smooth replicas, whereas PVC tape gave rough walls. A three-channel device molded on PMMA held two cell-laden gels in place with phase guides and supported the co-culture of cancer cells and fibroblasts under perfusion. Further analysis of flow laminarity and different mixer designs confirmed the robustness of this method. This workflow takes a digital design to a working de-vice within a day and lets biology laboratories adapt microfluidic devices to their experiments without the need of a clean room.

bioRxiv (Cold Spring Harbor Laboratory)
École Polytechnique Fédérale de Lausanne (CH)
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon