Automated Detection and Classification of Strabismus in Smartphone Images

Abstract Purpose Accurate detection of strabismus from smartphone images remains challenging, particularly in distinguishing true strabismus from pseudo-strabismus, in which apparent ocular misalignment is caused by facial anatomy rather than abnormal eye position. This study developed and evaluated a fully automated smartphone-based approach that explicitly models interocular asymmetry between the corneal light reflex (CLR) and pupil center for strabismus detection and classification. Methods A Mask R-CNN framework was trained to localize pupil centers and CLR positions from facial images. Geometric asymmetry parameters derived from the CLR-pupil relationship in the two eyes were used to detect strabismus and classify detected cases as horizontal or vertical deviations, with horizontal cases further classified as esotropia or exotropia. The final evaluation used a separate set of 205 clinically labeled smartphone images comprising orthotropic children, pseudo-strabismus cases, and children with strabismus. Results Of 110 orthotropic images, 107 were correctly classified as orthotropic, while 87 of 95 strabismic images were correctly identified. Overall strabismus detection accuracy was 94.63%, with 96.67% precision, 91.58% sensitivity, 97.27% specificity, and an F1-score of 94.06%. Horizontal-versus-vertical classification achieved 95.40% accuracy, and classification of horizontal strabismus as esotropia or exotropia achieved 96.15% accuracy. None of the 12 pseudo-strabismus cases in the test set was misclassified as strabismus. Conclusion Explicit modeling of interocular CLR-pupil asymmetry enables accurate automated detection and classification of strabismus from smartphone images and may help distinguish true strabismus from pseudo-strabismus. Following prospective clinical validation, this approach has potential to support accessible smartphone-based strabismus screening.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-09
DOI
https://doi.org/10.21203/rs.3.rs-11437464/v1
Primary Topic
Ophthalmology and Eye Disorders
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Automated Detection and Classification of Strabismus in Smartphone Images

Otman Basir, Brooke Koritala, Eileen E. Birch, Robert F. Hess³ et al.
Research Square
Ophthalmology and Eye Disorders
preprint

Automated Detection and Classification of Strabismus in Smartphone Images

Otman Basir, Brooke Koritala, Eileen E. Birch, Robert F. Hess³, Benjamin Thompson¹, Anoop Thazhathumanackal Radhakrishnan
preprint en

Abstract

Abstract Purpose Accurate detection of strabismus from smartphone images remains challenging, particularly in distinguishing true strabismus from pseudo-strabismus, in which apparent ocular misalignment is caused by facial anatomy rather than abnormal eye position. This study developed and evaluated a fully automated smartphone-based approach that explicitly models interocular asymmetry between the corneal light reflex (CLR) and pupil center for strabismus detection and classification. Methods A Mask R-CNN framework was trained to localize pupil centers and CLR positions from facial images. Geometric asymmetry parameters derived from the CLR-pupil relationship in the two eyes were used to detect strabismus and classify detected cases as horizontal or vertical deviations, with horizontal cases further classified as esotropia or exotropia. The final evaluation used a separate set of 205 clinically labeled smartphone images comprising orthotropic children, pseudo-strabismus cases, and children with strabismus. Results Of 110 orthotropic images, 107 were correctly classified as orthotropic, while 87 of 95 strabismic images were correctly identified. Overall strabismus detection accuracy was 94.63%, with 96.67% precision, 91.58% sensitivity, 97.27% specificity, and an F1-score of 94.06%. Horizontal-versus-vertical classification achieved 95.40% accuracy, and classification of horizontal strabismus as esotropia or exotropia achieved 96.15% accuracy. None of the 12 pseudo-strabismus cases in the test set was misclassified as strabismus. Conclusion Explicit modeling of interocular CLR-pupil asymmetry enables accurate automated detection and classification of strabismus from smartphone images and may help distinguish true strabismus from pseudo-strabismus. Following prospective clinical validation, this approach has potential to support accessible smartphone-based strabismus screening.

Research Square
University of Waterloo (CA), Retina Foundation of the Southwest (US), McGill University (CA)
Ophthalmology and Eye Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon