When Does Supervision Beat Reconstruction? Magnification Shift and the Robustness of AI Quality Control in Digital Pathology

Abstract Purpose Automated quality control of whole-slide images must stay reliable when scanning conditions change. We compared supervised probes on foundation-model features with generative reconstruction for artifact detection. Methods A linear probe on UNI2-h features and diffusion-reconstruction detectors adapted from PixCell used the same 16 annotated training slides. We evaluated them in cross-validation, on a 24-slide benchmark, on a blind 53-slide multi-cohort benchmark scored by its organizers, and on two external sets (289 cases; 2,127 images). Resampling to half resolution and back mimicked half magnification on the same tissue. We also assessed calibration and monitoring of the probe on known-clean slides. Results At matching magnification the probe was the better detector. It flagged no tissue on clean cross-validation slides, and on the blind benchmark its precision was 0.29 against 0.10 at similar Dice. Under resampling its false positives on clean tissue rose 227-fold on the benchmark and in every organ of the external images, while the reconstruction detectors’ did not; at matched false positives the ranking reversed. Its calibration error rose from 0.05 to 0.30. A second encoder, Phikon-v2, showed a 3.8-fold rise. Training the UNI2-h probe with resampled copies removed most of its rise but lowered accuracy on the original images. Rules combining both detectors inherited the probe’s failure. On known-clean slides the probe’s flagged-tissue fraction separated the 5× external set and resampled images (AUROC 0.94 and 0.89). Conclusions Laboratories using foundation-model probes for quality control should verify acquisition magnification, monitor the probe on clean tissue, and keep a reconstruction detector as a safeguard.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-09
DOI
https://doi.org/10.21203/rs.3.rs-11447191/v1
Primary Topic
AI in cancer detection
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

When Does Supervision Beat Reconstruction? Magnification Shift and the Robustness of AI Quality Control in Digital Pathology

Ilias G. Maglogiannis, Κωνσταντίνος Μούτσελος
Research Square
AI in cancer detection
preprint

When Does Supervision Beat Reconstruction? Magnification Shift and the Robustness of AI Quality Control in Digital Pathology

Ilias G. Maglogiannis, Κωνσταντίνος Μούτσελος
preprint en

Abstract

Abstract Purpose Automated quality control of whole-slide images must stay reliable when scanning conditions change. We compared supervised probes on foundation-model features with generative reconstruction for artifact detection. Methods A linear probe on UNI2-h features and diffusion-reconstruction detectors adapted from PixCell used the same 16 annotated training slides. We evaluated them in cross-validation, on a 24-slide benchmark, on a blind 53-slide multi-cohort benchmark scored by its organizers, and on two external sets (289 cases; 2,127 images). Resampling to half resolution and back mimicked half magnification on the same tissue. We also assessed calibration and monitoring of the probe on known-clean slides. Results At matching magnification the probe was the better detector. It flagged no tissue on clean cross-validation slides, and on the blind benchmark its precision was 0.29 against 0.10 at similar Dice. Under resampling its false positives on clean tissue rose 227-fold on the benchmark and in every organ of the external images, while the reconstruction detectors’ did not; at matched false positives the ranking reversed. Its calibration error rose from 0.05 to 0.30. A second encoder, Phikon-v2, showed a 3.8-fold rise. Training the UNI2-h probe with resampled copies removed most of its rise but lowered accuracy on the original images. Rules combining both detectors inherited the probe’s failure. On known-clean slides the probe’s flagged-tissue fraction separated the 5× external set and resampled images (AUROC 0.94 and 0.89). Conclusions Laboratories using foundation-model probes for quality control should verify acquisition magnification, monitor the probe on clean tissue, and keep a reconstruction detector as a safeguard.

Research Square
University of Piraeus (GR)
AI in cancer detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
When Does Supervision Beat Reconstruction? Magnification Shift and the Robustness of AI Quality Control in Digital Pathology — Ilias G. Maglogiannis, Κωνσταντίνος Μούτσελος · Research Square (2026) | TGRS Research Map | TGRS