Contamination-Aware Cross-Source and Cross-Architecture Benchmarking of Explainable AI for Brain-Tumor MRI Classification

Brain-tumor MRI classification and explainable artificial intelligence (XAI) evaluation can be affected by hidden source overlap and architecture-dependent explanation rankings. This study presents a focused contamination-aware, cross-source, and cross-architecture sensitivity study for brain-tumor MRI classification and post-hoc XAI. Three ImageNet-pretrained classifiers—ResNet-18, DenseNet-121, and ConvNeXt-Tiny—were trained exclusively on 3064 Cheng contrast-enhanced T1-weighted MRI slices using three random seeds. External evaluation used 4793 BRISC tumor images. A preceding image-level audit flagged 1070 BRISC images as possible or probable Cheng-related overlaps; therefore, performance was reported on BRISC-Full, an audit-retained subset of 3723 images, and the 1070-image flagged cohort. DenseNet-121 provided the strongest and most reproducible cross-source classification, achieving 90.34 ± 1.77% accuracy, 90.25 ± 1.79% macro-F1, and 0.9927 ± 0.0009 macro ROC-AUC on BRISC-Conservative. Removing flagged images reduced macro-F1 by 1.05–1.88 percentage points across architectures, while the flagged cohort was systematically easier, showing sensitivity to cohort selection without establishing a causal leakage effect. A comprehensive 15-method XAI benchmark on a pre-specified ResNet-18 showed that no technique dominated faithfulness, stability, and efficiency simultaneously: HiResCAM and LayerCAM offered the strongest overall quality–efficiency balance, whereas ScoreCAM achieved excellent stability at markedly higher computational cost. An eight-method common-correct cross-model benchmark revealed significant rank agreement between ResNet-18 and DenseNet-121 (Spearman ρ = 0.731, p = 0.040) and weaker estimated agreement involving ConvNeXt-Tiny, where Integrated Gradients became the leading method. Additional five-fold patient-separated Cheng evaluation yielded mean macro-F1 values of 0.913–0.936. In a distinct 12-method panel of 300 held-out Cheng images, overall rankings on 298 complete images gave ResNet–DenseNet agreement of 0.965 (95% CI 0.867–0.970), compared with 0.098 and 0.147 for pairs involving ConvNeXt. XAI features did not consistently improve a patient-separated error-referral task. These results support architecture- and protocol-specific interpretation of explanation reliability within the tested datasets.

Authors

Institutions

Publication Details

Journal
AI
Published
2026-11-09
DOI
https://doi.org/10.3390/ai7110466
Primary Topic
Explainable Artificial Intelligence (XAI)
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Contamination-Aware Cross-Source and Cross-Architecture Benchmarking of Explainable AI for Brain-Tumor MRI Classification

Ahmed Gawish, Yousuf Nasser Al Husaini, Mohammad Yasir Bin Taleb Abrar, Mohammed Abdulla Salim Al Husaini et al.
AI
Explainable Artificial Intelligence (XAI)
article

Contamination-Aware Cross-Source and Cross-Architecture Benchmarking of Explainable AI for Brain-Tumor MRI Classification

Ahmed Gawish, Yousuf Nasser Al Husaini, Mohammad Yasir Bin Taleb Abrar, Mohammed Abdulla Salim Al Husaini, Khawla Al Hassan, Maya Dawood
article en

Abstract

Brain-tumor MRI classification and explainable artificial intelligence (XAI) evaluation can be affected by hidden source overlap and architecture-dependent explanation rankings. This study presents a focused contamination-aware, cross-source, and cross-architecture sensitivity study for brain-tumor MRI classification and post-hoc XAI. Three ImageNet-pretrained classifiers—ResNet-18, DenseNet-121, and ConvNeXt-Tiny—were trained exclusively on 3064 Cheng contrast-enhanced T1-weighted MRI slices using three random seeds. External evaluation used 4793 BRISC tumor images. A preceding image-level audit flagged 1070 BRISC images as possible or probable Cheng-related overlaps; therefore, performance was reported on BRISC-Full, an audit-retained subset of 3723 images, and the 1070-image flagged cohort. DenseNet-121 provided the strongest and most reproducible cross-source classification, achieving 90.34 ± 1.77% accuracy, 90.25 ± 1.79% macro-F1, and 0.9927 ± 0.0009 macro ROC-AUC on BRISC-Conservative. Removing flagged images reduced macro-F1 by 1.05–1.88 percentage points across architectures, while the flagged cohort was systematically easier, showing sensitivity to cohort selection without establishing a causal leakage effect. A comprehensive 15-method XAI benchmark on a pre-specified ResNet-18 showed that no technique dominated faithfulness, stability, and efficiency simultaneously: HiResCAM and LayerCAM offered the strongest overall quality–efficiency balance, whereas ScoreCAM achieved excellent stability at markedly higher computational cost. An eight-method common-correct cross-model benchmark revealed significant rank agreement between ResNet-18 and DenseNet-121 (Spearman ρ = 0.731, p = 0.040) and weaker estimated agreement involving ConvNeXt-Tiny, where Integrated Gradients became the leading method. Additional five-fold patient-separated Cheng evaluation yielded mean macro-F1 values of 0.913–0.936. In a distinct 12-method panel of 300 held-out Cheng images, overall rankings on 298 complete images gave ResNet–DenseNet agreement of 0.965 (95% CI 0.867–0.970), compared with 0.098 and 0.147 for pairs involving ConvNeXt. XAI features did not consistently improve a patient-separated error-referral task. These results support architecture- and protocol-specific interpretation of explanation reliability within the tested datasets.

AIVol. 7(11)
Arab Open University (OM), Arab Open University (LB), Arab Open University (KW), Arab Open University (SA)
Explainable Artificial Intelligence (XAI)
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon