A set of high-frequency thermoelectric voltage converters with frequency-error compensation

High-frequency AC voltage measurement instrumentation fi nds limited application in the radio-electronic and defense industries, owing to considerable measurement errors induced by the parasitic reactive parameters of the measuring circuit. The pressing problem of enhancing the accuracy of RMS AC voltage measurements at frequencies exceeding 100 kHz is addressed herein. To resolve this problem, a method for compensating the frequency error of high-frequency thermoelectric voltage converters has been developed. For this purpose, a set of high-frequency thermoelectric voltage converters with frequency-error compensation has been developed and manufactured. The set comprises eight thermoelectric AC voltage converters designed for the following nominal voltage values: 0.5, 1, 2, 3, 5, 10, 20, and 30 V. The converters with nominal voltages from 1 V to 30 V incorporate additional resistors and adjustable structural capacitances controlled by a micrometric mechanism. The frequency-error compensation is described based on an analysis of the equivalent circuit as a section of a coaxial line with distributed parameters. The measurement equation is derived, the equivalent electrical circuit is presented, and experimental tests of the converter set are described. The measurement uncertainty of AC voltage using the developed converters is estimated. Based on the test results, it has been established that after individual capacitance adjustment, the relative error of AC voltage measurement did not exceed ±0.04 % at a frequency of 100 kHz and ±0.25 % in the frequency range of 1–30 MHz. At a coverage factor of two, the expanded uncertainty of the measurement results for converters with nominal voltages of 0.5–30 V at 100 kHz was 0.02 %. The obtained data confi rm the prospects of using the developed converter set as a secondary standard for the verifi cation of AC voltage measuring instruments.

Authors

Institutions

Publication Details

Journal
Izmeritel`naya Tekhnika
Published
2026-11-09
DOI
https://doi.org/10.32446/0368-1025it.2026-5-101-109
Primary Topic
Advanced Electrical Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A set of high-frequency thermoelectric voltage converters with frequency-error compensation

Vladimir Ivanovich Shevtsov, Alexander S. Katkov, S. A. Ivanov
Izmeritel`naya Tekhnika
Advanced Electrical Measurement Techniques
article

A set of high-frequency thermoelectric voltage converters with frequency-error compensation

Vladimir Ivanovich Shevtsov, Alexander S. Katkov, S. A. Ivanov
article en

Abstract

High-frequency AC voltage measurement instrumentation fi nds limited application in the radio-electronic and defense industries, owing to considerable measurement errors induced by the parasitic reactive parameters of the measuring circuit. The pressing problem of enhancing the accuracy of RMS AC voltage measurements at frequencies exceeding 100 kHz is addressed herein. To resolve this problem, a method for compensating the frequency error of high-frequency thermoelectric voltage converters has been developed. For this purpose, a set of high-frequency thermoelectric voltage converters with frequency-error compensation has been developed and manufactured. The set comprises eight thermoelectric AC voltage converters designed for the following nominal voltage values: 0.5, 1, 2, 3, 5, 10, 20, and 30 V. The converters with nominal voltages from 1 V to 30 V incorporate additional resistors and adjustable structural capacitances controlled by a micrometric mechanism. The frequency-error compensation is described based on an analysis of the equivalent circuit as a section of a coaxial line with distributed parameters. The measurement equation is derived, the equivalent electrical circuit is presented, and experimental tests of the converter set are described. The measurement uncertainty of AC voltage using the developed converters is estimated. Based on the test results, it has been established that after individual capacitance adjustment, the relative error of AC voltage measurement did not exceed ±0.04 % at a frequency of 100 kHz and ±0.25 % in the frequency range of 1–30 MHz. At a coverage factor of two, the expanded uncertainty of the measurement results for converters with nominal voltages of 0.5–30 V at 100 kHz was 0.02 %. The obtained data confi rm the prospects of using the developed converter set as a secondary standard for the verifi cation of AC voltage measuring instruments.

Izmeritel`naya TekhnikaVol. 75(5)
D.I. Mendeleyev All-Russian Institute for Metrology (RU)
Advanced Electrical Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon