Nuclear recoil separation in the photonuclear production of auger electron emitter Germanium-71 for high specific activity medical isotope production

Introduction The purity of a radionuclide is a crucial factor in the feasibility of medical isotope production methods. One measurement of purity is the ratio of the radionuclide of interest to all isotopes of the same element, or the specific activity. When the specific activity is too low, a sample can be unusable in medical applications due to inefficient radiolabeling with the intended radionuclide. A promising group of medical isotopes often produced with low specific activity are Auger electron (AE) emitting radionuclides. These radionuclides are often produced by irradiating a target material of the same element as the AE-emitting radionuclide of interest. Following such production methods, time-consuming and expensive mass separations would be needed to isotopically purify low specific activity products. Methods In this work, a new method of in-beam separation that relied on nuclear recoil and ultra-thin target foils was used to produce and separate AE-emitting germanium-71 (71Ge) from a natural germanium (natGe) target. Scientists at Idaho National Laboratory and Idaho State University have conducted photonuclear irradiation at the Idaho Accelerator Center to test this separation method by measuring the separation yield for 71Ge from natural Ge foils and to compare the measured separation yield to predictions from a nuclear recoil model. Results and Discussion With this targetry approach, a nuclear recoil efficiency of 0.13(4)% was measured for 71Ge from natural Ge foils. A comparable result of 0.23% was predicted for the recoil efficiency using analytical equations to describe the kinetics of the recoil effect. This work showed that the separation method is feasible, but due to low yields, further targetry development is necessary. Additionally, the modeling method can be used to guide future targetry development and experimental planning.

Authors

Institutions

Publication Details

Journal
Frontiers in Nuclear Engineering
Published
2026-11-09
DOI
https://doi.org/10.3389/fnuen.2026.1940142
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Nuclear recoil separation in the photonuclear production of auger electron emitter Germanium-71 for high specific activity medical isotope production

Nick H Erfurth, E. Paige Abel, Mason Jaussi
Frontiers in Nuclear Engineering
Radiopharmaceutical Chemistry and Applications
article

Nuclear recoil separation in the photonuclear production of auger electron emitter Germanium-71 for high specific activity medical isotope production

Nick H Erfurth, E. Paige Abel, Mason Jaussi
article en

Abstract

Introduction The purity of a radionuclide is a crucial factor in the feasibility of medical isotope production methods. One measurement of purity is the ratio of the radionuclide of interest to all isotopes of the same element, or the specific activity. When the specific activity is too low, a sample can be unusable in medical applications due to inefficient radiolabeling with the intended radionuclide. A promising group of medical isotopes often produced with low specific activity are Auger electron (AE) emitting radionuclides. These radionuclides are often produced by irradiating a target material of the same element as the AE-emitting radionuclide of interest. Following such production methods, time-consuming and expensive mass separations would be needed to isotopically purify low specific activity products. Methods In this work, a new method of in-beam separation that relied on nuclear recoil and ultra-thin target foils was used to produce and separate AE-emitting germanium-71 (71Ge) from a natural germanium (natGe) target. Scientists at Idaho National Laboratory and Idaho State University have conducted photonuclear irradiation at the Idaho Accelerator Center to test this separation method by measuring the separation yield for 71Ge from natural Ge foils and to compare the measured separation yield to predictions from a nuclear recoil model. Results and Discussion With this targetry approach, a nuclear recoil efficiency of 0.13(4)% was measured for 71Ge from natural Ge foils. A comparable result of 0.23% was predicted for the recoil efficiency using analytical equations to describe the kinetics of the recoil effect. This work showed that the separation method is feasible, but due to low yields, further targetry development is necessary. Additionally, the modeling method can be used to guide future targetry development and experimental planning.

Frontiers in Nuclear EngineeringVol. 5
Idaho State University (US), Idaho National Laboratory (US)
Radiopharmaceutical Chemistry and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon