One DXA scan limits the apparent accuracy of osteoporosis screening tools but explains at most 13% of what FDA-authorized radiograph devices miss

Abstract Purpose: Opportunistic screening tools, including three radiograph devices authorized by the US Food and Drug Administration (FDA), flag patients with low bone mineral density (BMD) for dual-energy X-ray absorptiometry (DXA), but are judged against one imperfect DXA scan. We asked how accurate a perfect classifier can look against one scan and whether this explains the devices' low sensitivity. Methods: From nationally representative US DXA data we estimated precision-error-free BMD and derived the single-scan frontier: the highest apparent sensitivity any test with errors independent of the scan's can show at each false-positive rate. We validated it in 515 repeat-scan pairs, split device shortfalls into reference and device parts, compared two corrections in 194 simulated scenarios and audited 228 published studies. Results: At national-survey precision, a perfect classifier showed apparent sensitivity of 0.695–0.945 across 24 strata, consistent with all 12 repeat-scan measures. In nine FDA strata, device sensitivity was 0.22–0.79 where the frontier was 0.90–1.00. Per 1,000 people screened, the devices missed 49–420 with DXA-defined low BMD, of whom DXA precision accounted for at most 27 (≤13% of the shortfall at guideline-minimum precision; 17% at national-survey precision). Device results flipped on repetition 2–5 times as often as DXA's would. Conditional-independence correction overstated sensitivity; latent-trait correction was unbiased given known precision and a correct model. Only 13 of 136 full-text studies mentioned DXA precision. Conclusion: One DXA scan makes even a perfect classifier look imperfect but explains little of the authorized devices' low sensitivity, so a negative device result should not replace DXA.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-09
DOI
https://doi.org/10.21203/rs.3.rs-11647445/v1
Primary Topic
Bone health and osteoporosis research
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

One DXA scan limits the apparent accuracy of osteoporosis screening tools but explains at most 13% of what FDA-authorized radiograph devices miss

Yunhao Jiang
Research Square
Bone health and osteoporosis research
preprint

One DXA scan limits the apparent accuracy of osteoporosis screening tools but explains at most 13% of what FDA-authorized radiograph devices miss

Yunhao Jiang
preprint en

Abstract

Abstract Purpose: Opportunistic screening tools, including three radiograph devices authorized by the US Food and Drug Administration (FDA), flag patients with low bone mineral density (BMD) for dual-energy X-ray absorptiometry (DXA), but are judged against one imperfect DXA scan. We asked how accurate a perfect classifier can look against one scan and whether this explains the devices' low sensitivity. Methods: From nationally representative US DXA data we estimated precision-error-free BMD and derived the single-scan frontier: the highest apparent sensitivity any test with errors independent of the scan's can show at each false-positive rate. We validated it in 515 repeat-scan pairs, split device shortfalls into reference and device parts, compared two corrections in 194 simulated scenarios and audited 228 published studies. Results: At national-survey precision, a perfect classifier showed apparent sensitivity of 0.695–0.945 across 24 strata, consistent with all 12 repeat-scan measures. In nine FDA strata, device sensitivity was 0.22–0.79 where the frontier was 0.90–1.00. Per 1,000 people screened, the devices missed 49–420 with DXA-defined low BMD, of whom DXA precision accounted for at most 27 (≤13% of the shortfall at guideline-minimum precision; 17% at national-survey precision). Device results flipped on repetition 2–5 times as often as DXA's would. Conditional-independence correction overstated sensitivity; latent-trait correction was unbiased given known precision and a correct model. Only 13 of 136 full-text studies mentioned DXA precision. Conclusion: One DXA scan makes even a perfect classifier look imperfect but explains little of the authorized devices' low sensitivity, so a negative device result should not replace DXA.

Research Square
University of Edinburgh (GB)
Bone health and osteoporosis research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
One DXA scan limits the apparent accuracy of osteoporosis screening tools but explains at most 13% of what FDA-authorized radiograph devices miss — Yunhao Jiang · Research Square (2026) | TGRS Research Map | TGRS