Monitoring Reduced Vigilance Using an Eyeglass-Type EEG System

An eyeglass-type electroencephalography (EEG) device has emerged as a promising platform for continuous cognitive state monitoring owing to its seamless integration into daily life and greater usability compared with conventional headset-style EEG systems. However, the feasibility of EEG-based reduced-vigilance monitoring using this form factor remains insufficiently examined. To address this issue, we conducted a two-phase experiment involving 21 participants to establish a mental fatigue-sensitive index and validate a monitoring algorithm for reduced vigilance associated with drowsiness or mental fatigue using a custom-made eyeglass-type EEG device. In the first phase, a long-term sustained attention task (d2 test) was employed to induce mental fatigue, and the ratio of low-alpha to high-beta power was identified as a potential biomarker of mental-fatigue-related vigilance decline. In the second phase, system performance was evaluated through a prolonged, monotonous video-watching experiment designed to elicit reduced vigilance. The algorithm combined the drowsiness detection index (theta-plus-alpha power) from the TP9 and TP10 channels with the candidate fatigue-sensitive index from the differential channel. Subject-specific calibration-based thresholds were used to generate index-specific segment-level decisions, which were combined using a logical OR rule. In the pseudo-real-time evaluation of 16 participants, the final fusion model achieved a mean accuracy of 70.31%, a false-positive rate of 10.40%, a recall of 49.67%, and a precision of 81.80%, calculated from participant-level metrics. Detection performance depended partly on the inclusion of segments with prolonged eye closure, with lower recall after their exclusion. Nevertheless, these findings provide preliminary evidence for the feasibility of detecting behaviorally defined reduced vigilance using an eyeglass-type EEG device.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-11-09
DOI
https://doi.org/10.3390/bios16110641
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Monitoring Reduced Vigilance Using an Eyeglass-Type EEG System

Ki‐Young Jung, Chang‐Hwan Im, Kyeonggu Lee, Hyeji Yu et al.
Biosensors
EEG and Brain-Computer Interfaces
article

Monitoring Reduced Vigilance Using an Eyeglass-Type EEG System

Ki‐Young Jung, Chang‐Hwan Im, Kyeonggu Lee, Hyeji Yu, Minsu Kim, Seohyeon Kim, Jonggyun Kim, Seung Min Lee, Hongjin Kim
article en

Abstract

An eyeglass-type electroencephalography (EEG) device has emerged as a promising platform for continuous cognitive state monitoring owing to its seamless integration into daily life and greater usability compared with conventional headset-style EEG systems. However, the feasibility of EEG-based reduced-vigilance monitoring using this form factor remains insufficiently examined. To address this issue, we conducted a two-phase experiment involving 21 participants to establish a mental fatigue-sensitive index and validate a monitoring algorithm for reduced vigilance associated with drowsiness or mental fatigue using a custom-made eyeglass-type EEG device. In the first phase, a long-term sustained attention task (d2 test) was employed to induce mental fatigue, and the ratio of low-alpha to high-beta power was identified as a potential biomarker of mental-fatigue-related vigilance decline. In the second phase, system performance was evaluated through a prolonged, monotonous video-watching experiment designed to elicit reduced vigilance. The algorithm combined the drowsiness detection index (theta-plus-alpha power) from the TP9 and TP10 channels with the candidate fatigue-sensitive index from the differential channel. Subject-specific calibration-based thresholds were used to generate index-specific segment-level decisions, which were combined using a logical OR rule. In the pseudo-real-time evaluation of 16 participants, the final fusion model achieved a mean accuracy of 70.31%, a false-positive rate of 10.40%, a recall of 49.67%, and a precision of 81.80%, calculated from participant-level metrics. Detection performance depended partly on the inclusion of segments with prolonged eye closure, with lower recall after their exclusion. Nevertheless, these findings provide preliminary evidence for the feasibility of detecting behaviorally defined reduced vigilance using an eyeglass-type EEG device.

BiosensorsVol. 16(11)
Kookmin University (KR), Seoul National University (KR), Seoul National University Hospital (KR), Hanyang University (KR), Pusan National University (KR)
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon