Influence of Treatment Time and Nitrogen Flow Rate on the Density Index and Porosity Potential of AA 380.0 Aluminum Alloy for High-Pressure Die Casting
A complete 3² factorial design was conducted with two replicates, totaling 18 experimental runs. The metallurgical quality was quantified by the Density Index (DI), determined by the hydrostatic method after a reduced pressure test (RPT). The DI reduced from 27.6 % (untreated bath) to 0.90 % after 720 s of degassing. Response Surface Methodology (RSM) modeling adjusted a second-order polynomial (R² = 98.54 %; adjusted R² = 97.94 %; predicted R² = 96.87 %), confirming statistical significance of time, flow, and time×flow interaction (p < 0.05). The thermodynamic analysis based on Sieverts’ Law showed a 36 % reduction in the equilibrium solubility of hydrogen due to the thermal drop of the bath (787 °C → 711 °C). The lowest experimental DI values were observed at T = 720 s and V ≈ 25 L/min.
Authors
- Juliano Cantarelli Toniolo (ORCID: https://orcid.org/0000-0002-8850-6481)
- Rodrigo Salib Rodrigues
Institutions
- Instituto Federal de Educação, Ciência e Tecnologia do Rio Grande do Sul (BR)
Publication Details
- Journal
- Revista Multidisciplinar do Nordeste Mineiro
- Published
- 2026-11-09
- DOI
- https://doi.org/10.66104/zkvyrq84
- Primary Topic
- Aluminum Alloy Microstructure Properties
- Type
- article
- Field-Weighted Citation Impact
- 0.00