Effects of As-built Interface Deviations on the Mechanical Behavior of Prestressed Concrete Inner Linings in High-pressure Water Conveyance Shield Tunnels: A Refined Three-dimensional Finite Element Study

High-pressure water conveyance shield tunnels may develop segment misalignment and geometric deviations at the interface between segmental linings and prestressed concrete inner linings. This study examined these effects in Contract B2 of the Pearl River Delta Water Resources Allocation Project. Field measurements informed a refined three-dimensional finite element model incorporating the surrounding rock, segmental lining and prestressed concrete inner lining. Circumferential stress responses were evaluated at representative circumferential locations and longitudinal sections during construction and water conveyance operation, including an operating internal water pressure of 1.3 MPa. The results indicated that, without misalignment, the inner lining remained in circumferential compression during both loading stages, although the end sections retained smaller compressive stress reserves than the middle section. Segment misalignment redistributed prestress and generated localised circumferential tensile stress concentrations, particularly near the crown and springlines at the tunnel ends. Tensile stresses could develop under some misalignment conditions described as satisfying assembly acceptance criteria. Ovality-related reductions in effective lining thickness also changed circumferential stresses, with a more pronounced response in the outer layer. Numerical design checks incorporating a prestressing-strand bending-moment amplification factor of 1.9 and a conventional-reinforcement safety-factor correction factor of 1.1 indicated improved cracking resistance under the assessed unfavourable conditions. These findings support supplementary structural checks of sensitive inner-lining regions rather than reliance on segment assembly tolerances alone.

Authors

Institutions

Publication Details

Journal
Advances in Research
Published
2026-11-09
DOI
https://doi.org/10.9734/air/2026/v27i61771
Primary Topic
Geotechnical Engineering and Underground Structures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Effects of As-built Interface Deviations on the Mechanical Behavior of Prestressed Concrete Inner Linings in High-pressure Water Conveyance Shield Tunnels: A Refined Three-dimensional Finite Element Study

Duan Han
Advances in Research
Geotechnical Engineering and Underground Structures
article

Effects of As-built Interface Deviations on the Mechanical Behavior of Prestressed Concrete Inner Linings in High-pressure Water Conveyance Shield Tunnels: A Refined Three-dimensional Finite Element Study

Duan Han
article en

Abstract

High-pressure water conveyance shield tunnels may develop segment misalignment and geometric deviations at the interface between segmental linings and prestressed concrete inner linings. This study examined these effects in Contract B2 of the Pearl River Delta Water Resources Allocation Project. Field measurements informed a refined three-dimensional finite element model incorporating the surrounding rock, segmental lining and prestressed concrete inner lining. Circumferential stress responses were evaluated at representative circumferential locations and longitudinal sections during construction and water conveyance operation, including an operating internal water pressure of 1.3 MPa. The results indicated that, without misalignment, the inner lining remained in circumferential compression during both loading stages, although the end sections retained smaller compressive stress reserves than the middle section. Segment misalignment redistributed prestress and generated localised circumferential tensile stress concentrations, particularly near the crown and springlines at the tunnel ends. Tensile stresses could develop under some misalignment conditions described as satisfying assembly acceptance criteria. Ovality-related reductions in effective lining thickness also changed circumferential stresses, with a more pronounced response in the outer layer. Numerical design checks incorporating a prestressing-strand bending-moment amplification factor of 1.9 and a conventional-reinforcement safety-factor correction factor of 1.1 indicated improved cracking resistance under the assessed unfavourable conditions. These findings support supplementary structural checks of sensitive inner-lining regions rather than reliance on segment assembly tolerances alone.

Advances in ResearchVol. 27(6)
North China University of Water Resources and Electric Power (CN)
Geotechnical Engineering and Underground Structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon