Accelerometer- and Gyroscope-Based Sensor System for Detecting Swallowing, Speaking, and Coughing Events in ICU Patients

(1) Background: Swallowing, coughing, and speaking are clinically relevant physiological events, but they are not routinely and continuously monitored in intensive care. This study evaluates the feasibility of detecting these events using inertial measurement unit (IMU) signals acquired from the cricoid and thoracic regions. (2) Methods: Data were collected from 29 patients in the intensive care unit (ICU) during predefined swallowing, coughing, speaking, and movement tasks. A classical machine learning pipeline was developed and evaluated using leave-one-patient-out cross-validation. (3) Results: Cricoid and thoracic accelerometer signals were informative for event detection, with the thoracic sensor particularly contributing to cough detection. Speaking (F1=0.80), coughing (F1=0.72), and aggregated swallowing (F1=0.74) were detected in this controlled experimental setting. (4) Conclusions: The results support the feasibility of IMU-based detection of prompted swallowing, coughing, and speaking events in ICU patients. Further validation under spontaneous and clinically heterogeneous conditions is required before continuous clinical monitoring can be assessed.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-11-09
DOI
https://doi.org/10.3390/s26217089
Primary Topic
Context-Aware Activity Recognition Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Accelerometer- and Gyroscope-Based Sensor System for Detecting Swallowing, Speaking, and Coughing Events in ICU Patients

Pascal Verdonck, Marija Stojchevska, Sofie Van Hoecke, Guylian Stevens et al.
Sensors
Context-Aware Activity Recognition Systems
article

Accelerometer- and Gyroscope-Based Sensor System for Detecting Swallowing, Speaking, and Coughing Events in ICU Patients

Pascal Verdonck, Marija Stojchevska, Sofie Van Hoecke, Guylian Stevens, Jonas Van Der Donckt, Stijn Van de Velde, Constantijn Coppers
article en

Abstract

(1) Background: Swallowing, coughing, and speaking are clinically relevant physiological events, but they are not routinely and continuously monitored in intensive care. This study evaluates the feasibility of detecting these events using inertial measurement unit (IMU) signals acquired from the cricoid and thoracic regions. (2) Methods: Data were collected from 29 patients in the intensive care unit (ICU) during predefined swallowing, coughing, speaking, and movement tasks. A classical machine learning pipeline was developed and evaluated using leave-one-patient-out cross-validation. (3) Results: Cricoid and thoracic accelerometer signals were informative for event detection, with the thoracic sensor particularly contributing to cough detection. Speaking (F1=0.80), coughing (F1=0.72), and aggregated swallowing (F1=0.74) were detected in this controlled experimental setting. (4) Conclusions: The results support the feasibility of IMU-based detection of prompted swallowing, coughing, and speaking events in ICU patients. Further validation under spontaneous and clinically heterogeneous conditions is required before continuous clinical monitoring can be assessed.

SensorsVol. 26(21)
Ghent University (BE), IMEC (BE), AZ Maria Middelares (BE)
Context-Aware Activity Recognition Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon