Development of solid reinforced porous femoral components made using electron beam powder bed fusion to meet endurance requirement

Abstract Solid stemmed femoral components are currently used, although they can be porous-coated. A highly porous component can enhance the long-term fixation of the implant through bone in-growth. Electron beam powder bed fusion (EBPBF) is capable of fabricating porous structures. However, a femoral component also needs to function under a highly critical loading condition. In this study, design/simulation, EBPBF and fatigue testing were conducted in order to develop satisfactory and highly porous Ti6Al4V femoral components. Loading during testing has closely followed that set by the international standard for femoral components. After the initial design, EBPBF and testing, a final design was made through topological optimisation and components were made. Tests have shown that two components have satisfied the requirement well (cycle number N > 5 x10 7 ) and two have failed each with a failure cycle number (N f ) slightly lower in logarithmic scale than the required (N f >5 x10 6 cycles). Then, an attempt has been made to explain the effect of EBPBF defect on N f using the Kitagawa-Takahashi (K-T) diagram approach through (a) tests to determine the threshold stress intensity factor, (b) fractography and micro-CT to locate the defects and measure the defect sizes, (c) close evaluation of stress in defect locations by simulation. It has been shown that the effect of defects affecting N f in a real component could approximately, although not highly accurately, be explained using the K-T diagram approach. The present findings may suggest how highly porous EMPBF femoral components can be designed, built and quality assured to satisfy the fatigue life requirement.

Authors

Institutions

Publication Details

Journal
The International Journal of Advanced Manufacturing Technology
Published
2026-11-09
DOI
https://doi.org/10.1007/s00170-026-19515-2
Primary Topic
Additive Manufacturing Materials and Processes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Development of solid reinforced porous femoral components made using electron beam powder bed fusion to meet endurance requirement

Philipp Nieke, Yawen Huang, ZHAN WEN CHEN
3 links
The International Journal of Advanced Manufacturing Technology
Additive Manufacturing Materials and Processes
article

Development of solid reinforced porous femoral components made using electron beam powder bed fusion to meet endurance requirement

Philipp Nieke, Yawen Huang, ZHAN WEN CHEN
article en

Abstract

Abstract Solid stemmed femoral components are currently used, although they can be porous-coated. A highly porous component can enhance the long-term fixation of the implant through bone in-growth. Electron beam powder bed fusion (EBPBF) is capable of fabricating porous structures. However, a femoral component also needs to function under a highly critical loading condition. In this study, design/simulation, EBPBF and fatigue testing were conducted in order to develop satisfactory and highly porous Ti6Al4V femoral components. Loading during testing has closely followed that set by the international standard for femoral components. After the initial design, EBPBF and testing, a final design was made through topological optimisation and components were made. Tests have shown that two components have satisfied the requirement well (cycle number N > 5 x10 7 ) and two have failed each with a failure cycle number (N f ) slightly lower in logarithmic scale than the required (N f >5 x10 6 cycles). Then, an attempt has been made to explain the effect of EBPBF defect on N f using the Kitagawa-Takahashi (K-T) diagram approach through (a) tests to determine the threshold stress intensity factor, (b) fractography and micro-CT to locate the defects and measure the defect sizes, (c) close evaluation of stress in defect locations by simulation. It has been shown that the effect of defects affecting N f in a real component could approximately, although not highly accurately, be explained using the K-T diagram approach. The present findings may suggest how highly porous EMPBF femoral components can be designed, built and quality assured to satisfy the fatigue life requirement.

The International Journal of Advanced Manufacturing Technology
Auckland University of Technology (NZ)
Auckland University of Technology, New Zealand
Industry, innovation and infrastructure, Good health and well-being
Additive Manufacturing Materials and Processes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon