Multidirectional x-ray phase-contrast imaging with 1D modulators
Beam-tracking (BT) is an x-ray phase-contrast imaging technique that requires a single absorption mask, making it simpler to implement than approaches relying on two or more masks or gratings, such as edge-illumination or grating interferometry. Conventional 1D-BT, based on linear masks splitting the beam into individual beamlets, is sensitive to refraction and dark-field signals only along the direction transverse to the beamlets, while multidirectional sensitivity requires 2D masks. However, 2D masks suffer from reduced photon transmission and a quadratic increase in the number of stepping positions needed for full sample illumination, resulting in longer acquisition times. Here, we present multi1D-BT, an acquisition scheme that achieves multidirectional sensitivity in the transmission and differential phase (refraction) channels using a 1D mask, by combining two consecutive acquisitions rotated 90° with respect to each other. The method is validated on a polymethyl methacrylate test phantom and an ex vivo insect specimen, comparing multi1D-BT against 2D-BT acquisitions obtained with 2D structured modulators with (nearly) matching periods and apertures. In our experiments, multi1D-BT achieved a three times faster acquisition with similar or better image quality compared to conventional 2D-BT: the signal-to-noise ratio in the refraction signal was 35%–70% higher, and up to two times higher when compared at matched exposure time, while the contrast-to-noise ratio in the transmission signal was more than doubled. These findings indicate that multi1D-BT can provide fast, multidirectional differential phase and transmission imaging using simpler and more widely available 1D modulators, at the cost of requiring image registration between the two orthogonal acquisitions.
Authors
- Ashkan Ajeer (ORCID: https://orcid.org/0000-0002-5942-8613)
- Andrew Coathup (ORCID: https://orcid.org/0000-0001-5169-7512)
- Marco Endrizzi (ORCID: https://orcid.org/0000-0002-7810-2301)
- Luca Brombal (ORCID: https://orcid.org/0000-0002-4009-8191)
- P. Perion (ORCID: https://orcid.org/0009-0008-1378-5288)
- Cristian David Tibambre Heredia (ORCID: https://orcid.org/0009-0002-9242-3897)
Institutions
- The Abdus Salam International Centre for Theoretical Physics (ICTP) (IT)
- University of Trieste (IT)
- Istituto Nazionale di Fisica Nucleare (IT)
- Universidad de Los Andes (CO)
- Istituto Nazionale di Fisica Nucleare, Sezione di Trieste (IT)
- University College London (GB)
Publication Details
- Journal
- Applied Physics Letters
- Published
- 2026-11-09
- DOI
- https://doi.org/10.1063/5.0354473
- Primary Topic
- Advanced X-ray Imaging Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Ministero dell'Università e della Ricerca
- Engineering and Physical Sciences Research Council