Open-system versus unitary density-matrix predictors on long-horizon predictive error: a pre-registered comparison against an exact Bayes reference

Technical report; not peer reviewed (internal review only). On synthetic partially observed Markov processes with an exact Bayes reference and about 10³ parameters, we compare unitary and open-system (GKSL, Kraus-channel, contraction-only) density-matrix belief predictors, trained on horizons 1–50 and evaluated to 200, by excess predictive error against the Bayes predictor. Pre-registered, over ten seeds under the registered learning-rate selection, a unitary predictor whose blind rollout does not marginalise its observation instrument carried 0.0237 nats more extrapolation-window error than the GKSL predictor on the simple task, meeting the 0.02-nat threshold; on the metastable task the excess was 0.0189 nats, below the threshold. In these near-stationary configurations, contraction towards a stationary state removed most of the excess; the general GKSL generator added nothing beyond it in the registered windows, and neither a recurrence mechanism nor a dose–response in the environment dimension was established. Post hoc, applying the instrument's non-selective channel at each blind step removed nearly all of the excess. In a matched-parameter comparison, density-matrix sequence models did not meet the pre-registered margin over flexible classical recurrent networks on any arm or budget, and that comparison's registered conclusion is not accepted because its positive control failed. In a pre-registered follow-up, a moment-matching warm start let the true-order density-matrix model capture at least 90% of the predictable information on 10 of 10 fresh seeds of one HQMM-generated process, with a recipe developed on exploratory seeds of that process, and on 0 of 10 for a weaker-signal instance. Neither the limitation nor the remedy is new. Licences: report, text and own data CC BY 4.0; supplement code Apache-2.0; third-party data keep their own licences.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-07
DOI
https://doi.org/10.5281/zenodo.24050452
Primary Topic
Quantum Mechanics and Applications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Open-system versus unitary density-matrix predictors on long-horizon predictive error: a pre-registered comparison against an exact Bayes reference

Jiaxuan Chen
Zenodo (CERN European Organization for Nuclear Research)
Quantum Mechanics and Applications
preprint

Open-system versus unitary density-matrix predictors on long-horizon predictive error: a pre-registered comparison against an exact Bayes reference

Jiaxuan Chen
preprint en

Abstract

Technical report; not peer reviewed (internal review only). On synthetic partially observed Markov processes with an exact Bayes reference and about 10³ parameters, we compare unitary and open-system (GKSL, Kraus-channel, contraction-only) density-matrix belief predictors, trained on horizons 1–50 and evaluated to 200, by excess predictive error against the Bayes predictor. Pre-registered, over ten seeds under the registered learning-rate selection, a unitary predictor whose blind rollout does not marginalise its observation instrument carried 0.0237 nats more extrapolation-window error than the GKSL predictor on the simple task, meeting the 0.02-nat threshold; on the metastable task the excess was 0.0189 nats, below the threshold. In these near-stationary configurations, contraction towards a stationary state removed most of the excess; the general GKSL generator added nothing beyond it in the registered windows, and neither a recurrence mechanism nor a dose–response in the environment dimension was established. Post hoc, applying the instrument's non-selective channel at each blind step removed nearly all of the excess. In a matched-parameter comparison, density-matrix sequence models did not meet the pre-registered margin over flexible classical recurrent networks on any arm or budget, and that comparison's registered conclusion is not accepted because its positive control failed. In a pre-registered follow-up, a moment-matching warm start let the true-order density-matrix model capture at least 90% of the predictable information on 10 of 10 fresh seeds of one HQMM-generated process, with a recipe developed on exploratory seeds of that process, and on 0 of 10 for a weaker-signal instance. Neither the limitation nor the remedy is new. Licences: report, text and own data CC BY 4.0; supplement code Apache-2.0; third-party data keep their own licences.

Zenodo (CERN European Organization for Nuclear Research)
Quantum Mechanics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon