Analytical Quality by Design-Guided Development and Validation of Stability-Indicating RP-HPLC Method for the Simultaneous Quantification of Saquinavir and Tipranavir in Pharmaceutical Formulations

Objective: To develop and validate a robust and stability-indicating RP-HPLC method for the simultaneous estimation of Saquinavir and Tipranavir in pharmaceutical formulations using an Analytical Quality by Design (AQbD) approach. Methods: Chromatographic conditions were optimized using a Box–Behnken design by evaluating mobile phase composition, buffer pH and flow rate as critical method parameters. The optimized method employed a Inertsil C18 column (250 mm × 4.6 mm, 5 µm particle size) with methanol and phosphate buffer (65:35, v/v; pH 3.5) at a flow rate of 1.0 ml/min and detection at 248 nm. The method was validated according to ICH Q2(R1) guidelines for specificity, linearity, accuracy, precision, sensitivity, robustness, and stability-indicating capability. Forced-degradation studies were performed under different stress conditions. ² values of 0.9992 for Saquinavir and 0.9995 for Tipranavir. Accuracy was satisfactory, with recoveries of 98–102%, while precision showed %RSD values below 2%. The method exhibited good sensitivity with low detection and quantification limits. Forced-degradation studies demonstrated effective separation of degradation products from the drug peaks, confirming the stability-indicating capability. The method remained Results: The method showed excellent linearity with r reliable under deliberate variations in chromatographic conditions. Conclusion: The developed AQbD-based RP-HPLC method was successfully validated and demonstrated satisfactory specificity, linearity, accuracy, precision, sensitivity, robustness, and stability-indicating capability. The method is suitable for routine quality control and stability assessment of Saquinavir and Tipranavir in pharmaceutical formulations.

Authors

Institutions

Publication Details

Journal
International Journal of Applied Pharmaceutics
Published
2026-11-07
DOI
https://doi.org/10.22159/ijap.2026v18i6.59771
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Analytical Quality by Design-Guided Development and Validation of Stability-Indicating RP-HPLC Method for the Simultaneous Quantification of Saquinavir and Tipranavir in Pharmaceutical Formulations

Kondreddy Vinod Kumar, G. USHASREE
International Journal of Applied Pharmaceutics
Analytical Methods in Pharmaceuticals
article

Analytical Quality by Design-Guided Development and Validation of Stability-Indicating RP-HPLC Method for the Simultaneous Quantification of Saquinavir and Tipranavir in Pharmaceutical Formulations

Kondreddy Vinod Kumar, G. USHASREE
article en

Abstract

Objective: To develop and validate a robust and stability-indicating RP-HPLC method for the simultaneous estimation of Saquinavir and Tipranavir in pharmaceutical formulations using an Analytical Quality by Design (AQbD) approach. Methods: Chromatographic conditions were optimized using a Box–Behnken design by evaluating mobile phase composition, buffer pH and flow rate as critical method parameters. The optimized method employed a Inertsil C18 column (250 mm × 4.6 mm, 5 µm particle size) with methanol and phosphate buffer (65:35, v/v; pH 3.5) at a flow rate of 1.0 ml/min and detection at 248 nm. The method was validated according to ICH Q2(R1) guidelines for specificity, linearity, accuracy, precision, sensitivity, robustness, and stability-indicating capability. Forced-degradation studies were performed under different stress conditions. ² values of 0.9992 for Saquinavir and 0.9995 for Tipranavir. Accuracy was satisfactory, with recoveries of 98–102%, while precision showed %RSD values below 2%. The method exhibited good sensitivity with low detection and quantification limits. Forced-degradation studies demonstrated effective separation of degradation products from the drug peaks, confirming the stability-indicating capability. The method remained Results: The method showed excellent linearity with r reliable under deliberate variations in chromatographic conditions. Conclusion: The developed AQbD-based RP-HPLC method was successfully validated and demonstrated satisfactory specificity, linearity, accuracy, precision, sensitivity, robustness, and stability-indicating capability. The method is suitable for routine quality control and stability assessment of Saquinavir and Tipranavir in pharmaceutical formulations.

International Journal of Applied Pharmaceutics
Jawaharlal Nehru Technological University Anantapur (IN)
Openalex Percentile: Top 26%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon