Stability of an astigmatic correction choice: a finite-menu analysis

Preprint — not peer reviewed. This mathematical report examines whether a preferred astigmatic correction remains preferred throughout a stated uncertainty set. It applies established nearest-point and support-function geometry to a fixed, finite correction menu, and separates predicted residual cylinder, stability of the choice, and the largest excess squared residual from retaining it. An exact rational-arithmetic implementation check covered 1,600 constructed cases and 1,995 nominal-choice comparisons, with agreement between formula-based and direct squared-loss calculations. The package provides the manuscript, mathematical derivation, local protocol, verification source and recorded output. These are constructed mathematical cases, not patients. The uncertainty sets are not independently calibrated, and the work does not estimate postoperative accuracy, visual benefit or spectacle independence. Squared-loss regret has units D²; its square root is not additional residual cylinder. The manuscript describes AI assistance with research, preparation and editing, mathematical derivation and Python code.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-08
DOI
https://doi.org/10.5281/zenodo.24062580
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Stability of an astigmatic correction choice: a finite-menu analysis

Vitor Moreira Torturella, Danyelle Machado Hott
1 links
Zenodo (CERN European Organization for Nuclear Research)
Ophthalmology and Visual Impairment Studies
preprint

Stability of an astigmatic correction choice: a finite-menu analysis

Vitor Moreira Torturella, Danyelle Machado Hott
preprint en

Abstract

Preprint — not peer reviewed. This mathematical report examines whether a preferred astigmatic correction remains preferred throughout a stated uncertainty set. It applies established nearest-point and support-function geometry to a fixed, finite correction menu, and separates predicted residual cylinder, stability of the choice, and the largest excess squared residual from retaining it. An exact rational-arithmetic implementation check covered 1,600 constructed cases and 1,995 nominal-choice comparisons, with agreement between formula-based and direct squared-loss calculations. The package provides the manuscript, mathematical derivation, local protocol, verification source and recorded output. These are constructed mathematical cases, not patients. The uncertainty sets are not independently calibrated, and the work does not estimate postoperative accuracy, visual benefit or spectacle independence. Squared-loss regret has units D²; its square root is not additional residual cylinder. The manuscript describes AI assistance with research, preparation and editing, mathematical derivation and Python code.

Zenodo (CERN European Organization for Nuclear Research)
Universidade do Estado do Rio de Janeiro (BR)
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon