Design Space–Guided Chiral Chromatographic Method Development for Enantiomeric Resolution and Purity Assessment Thereby Monitoring the Active S-Isomer of Pirtobrutinib by LC-MS/MS

Objective: Quality by Design (QbD) was used to develop, test, and optimize a reliable normal phase high-performance liquid chromatography (NP-HPLC) method for distinguishing R-and S-isomers in bulk pharmaceutical and therapeutic formulations. Separating and quantifying the enantiomers of Jaypirca, the next-generation non-covalent Bruton’s Tyrosine Kinase (BTK) inhibitor, is essential. Methods: A YMC Chiral ART Cellulose-SC column (250×4.6 mm, 5 µm) was utilized for chromatographic separation. At 35 °C, 1.5 ml/min of acetonitrile with 0.1% diethylamine (100:0.1 v/v) was added. R-and S-isomers showed symmetrical peaks at 4.42 and 6.21 min of retention time. The 3² full factorial design showed that acetonitrile composition and flow rate greatly affected retention time and resolution (Model F-values 674.76 and 1177.55; p=0.0001). Results: Models with precision ratios of 61.29 and 75.35 showed high signal dependability and excellent data fit (R²=0.9985 for retention time and 0.9986 for resolution). Under optimal conditions, a resolution of over 5 was regularly reached, observed linearity across 1.0 to 3.5 µg/ml with a R² value of above 0.9999. The quantification limit (LOQ) was 1.0 µg/ml with signal-to-noise ratios of 18.05 and 13.54, while the detection limit (LOD) was 0.5 µg/ml with 6.34 and 4.71. Precision experiments showed %RSD<2% for suitability with system, with accuracy ranging from 98.1 to 101.8%. The Jaypirca tablet assay recovered 99.7% of the active S-isomer with m/z 480.15→400.02. Conclusion: Beyond quality monitoring, chiral separation supports regulatory compliance, stability and racemization studies, impurity profiling, process optimization, and stereoselective synthesis. The validated NP-HPLC method ensures enantiomeric purity and selective production of the pharmacologically active S-isomer.

Authors

Publication Details

Journal
International Journal of Applied Pharmaceutics
Published
2026-11-07
DOI
https://doi.org/10.22159/ijap.2026v18i6.59307
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Design Space–Guided Chiral Chromatographic Method Development for Enantiomeric Resolution and Purity Assessment Thereby Monitoring the Active S-Isomer of Pirtobrutinib by LC-MS/MS

Akunuri Ujwala, DANDU VENKATA SAI PRAMEELA, KUMARASWAMY GANDLA
International Journal of Applied Pharmaceutics
Analytical Chemistry and Chromatography
article

Design Space–Guided Chiral Chromatographic Method Development for Enantiomeric Resolution and Purity Assessment Thereby Monitoring the Active S-Isomer of Pirtobrutinib by LC-MS/MS

Akunuri Ujwala, DANDU VENKATA SAI PRAMEELA, KUMARASWAMY GANDLA
article en

Abstract

Objective: Quality by Design (QbD) was used to develop, test, and optimize a reliable normal phase high-performance liquid chromatography (NP-HPLC) method for distinguishing R-and S-isomers in bulk pharmaceutical and therapeutic formulations. Separating and quantifying the enantiomers of Jaypirca, the next-generation non-covalent Bruton’s Tyrosine Kinase (BTK) inhibitor, is essential. Methods: A YMC Chiral ART Cellulose-SC column (250×4.6 mm, 5 µm) was utilized for chromatographic separation. At 35 °C, 1.5 ml/min of acetonitrile with 0.1% diethylamine (100:0.1 v/v) was added. R-and S-isomers showed symmetrical peaks at 4.42 and 6.21 min of retention time. The 3² full factorial design showed that acetonitrile composition and flow rate greatly affected retention time and resolution (Model F-values 674.76 and 1177.55; p=0.0001). Results: Models with precision ratios of 61.29 and 75.35 showed high signal dependability and excellent data fit (R²=0.9985 for retention time and 0.9986 for resolution). Under optimal conditions, a resolution of over 5 was regularly reached, observed linearity across 1.0 to 3.5 µg/ml with a R² value of above 0.9999. The quantification limit (LOQ) was 1.0 µg/ml with signal-to-noise ratios of 18.05 and 13.54, while the detection limit (LOD) was 0.5 µg/ml with 6.34 and 4.71. Precision experiments showed %RSD<2% for suitability with system, with accuracy ranging from 98.1 to 101.8%. The Jaypirca tablet assay recovered 99.7% of the active S-isomer with m/z 480.15→400.02. Conclusion: Beyond quality monitoring, chiral separation supports regulatory compliance, stability and racemization studies, impurity profiling, process optimization, and stereoselective synthesis. The validated NP-HPLC method ensures enantiomeric purity and selective production of the pharmacologically active S-isomer.

International Journal of Applied Pharmaceutics
Openalex Percentile: Top 26%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon