Mapping and Outcome Implications of Left Atrial Low Voltage Regions as Determined by a Novel 122-electrode Spherical Mapping and Ablation Catheter

Abstract Aims A novel 122-electrode spherical mapping/pulsed field ablation (PFA) device is known to effectively ablate atrial fibrillation (AF). The aim of this study is threshold optimization of LVA for the unique geometry of the Globe electrodes and the prognostic association, to evaluate if the extent of low voltage areas could predict recurrence. Methods and Results The PULSAR study was an IDE trial of 183 patients undergoing first-time paroxysmal AF ablation with one-year outcomes of any atrial arrhythmia. During this study, a subset of patients (n=82) had detailed pre-ablation voltage maps performed with the catheter. Pulmonary vein isolation (PVI) was then performed with PFA. Patients were followed with weekly transtelephonic monitoring, ECG, and Holters at 3, 6, and 12 months. Recurrence was defined as any atrial arrhythmia (AA) > 30 seconds. Receiver operator curve (ROC) analysis revealed that a low voltage threshold of 1.0 mV had the highest value (0.735). The percentage LVA surface area resulting from a threshold of 1.0 mV that predicted AA recurrence was 11.6%. Univariate and multivariate analysis revealed the percentage LVA was the strongest predictor of AA recurrence. The 12-month freedom from AA was 84.6% and 52.9% for subjects under and over the low voltage area threshold respectively. Conclusions A voltage threshold of 1.0 mV is proposed as a threshold for defining LVA using the spherical catheter, but a range of approximately 0.5-1.5 mV yielded similar performance. Increased low voltage area in the pre-ablation atrial map was associated with a higher risk of AA recurrence.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2026-11-06
DOI
https://doi.org/10.1093/europace/euag315
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Mapping and Outcome Implications of Left Atrial Low Voltage Regions as Determined by a Novel 122-electrode Spherical Mapping and Ablation Catheter

Marc William Deyell, Christopher E. Woods, Petr Neužil, Srinivas Rao Dukkipati et al.
EP Europace
Atrial Fibrillation Management and Outcomes
article

Mapping and Outcome Implications of Left Atrial Low Voltage Regions as Determined by a Novel 122-electrode Spherical Mapping and Ablation Catheter

Marc William Deyell, Christopher E. Woods, Petr Neužil, Srinivas Rao Dukkipati, Hugh G Calkins, Hans Kottkamp, Atul Verma, Ayman Ali Hussein, Philipp Sommer, José Osorio, Vivek Yerrapu Reddy, Devi G. Nair, Burghard Schumacher, Saumil R. Oza
article en

Abstract

Abstract Aims A novel 122-electrode spherical mapping/pulsed field ablation (PFA) device is known to effectively ablate atrial fibrillation (AF). The aim of this study is threshold optimization of LVA for the unique geometry of the Globe electrodes and the prognostic association, to evaluate if the extent of low voltage areas could predict recurrence. Methods and Results The PULSAR study was an IDE trial of 183 patients undergoing first-time paroxysmal AF ablation with one-year outcomes of any atrial arrhythmia. During this study, a subset of patients (n=82) had detailed pre-ablation voltage maps performed with the catheter. Pulmonary vein isolation (PVI) was then performed with PFA. Patients were followed with weekly transtelephonic monitoring, ECG, and Holters at 3, 6, and 12 months. Recurrence was defined as any atrial arrhythmia (AA) > 30 seconds. Receiver operator curve (ROC) analysis revealed that a low voltage threshold of 1.0 mV had the highest value (0.735). The percentage LVA surface area resulting from a threshold of 1.0 mV that predicted AA recurrence was 11.6%. Univariate and multivariate analysis revealed the percentage LVA was the strongest predictor of AA recurrence. The 12-month freedom from AA was 84.6% and 52.9% for subjects under and over the low voltage area threshold respectively. Conclusions A voltage threshold of 1.0 mV is proposed as a threshold for defining LVA using the spherical catheter, but a range of approximately 0.5-1.5 mV yielded similar performance. Increased low voltage area in the pre-ablation atrial map was associated with a higher risk of AA recurrence.

EP Europace
Cleveland Clinic (US), Ascension (US), Mount Sinai Hospital (US), University of British Columbia (CA), Johns Hopkins University (US), Heart and Diabetes Center North Rhine-Westphalia (DE), McGill University Health Centre (CA), California Pacific Medical Center (US), Westpfalz Klinikum (DE), Na Homolce Hospital (CZ), Clinical Pharmacology of Miami (US), Johns Hopkins Hospital (US), St. Vincent's Medical Center (US), Ruhr University Bochum (DE)
Openalex Percentile: Top 12%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon