Comparative diagnostic accuracy of InfraScanner in paediatric versus adult traumatic brain injury: A prospective, computed tomography–validated study

Objective: To compare the diagnostic accuracy of InfraScanner against computed tomography (CT) for detection of intracranial haematoma in paediatric versus adult patients with traumatic brain injury (TBI), and to identify lesion-level predictors of device detection. Methodology: This prospective observational, CT-validated study recruited 400 consecutive TBI patients (200 paediatric, 200 adult) at the Department of Neurosurgery, Lady Reading Hospital – Medical Teaching Institution (MTI), Peshawar from January 2025 to June 2025. Blinded InfraScanner Model 2000 and CT assessments were performed within one hour of each other. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated using 95% Wilson confidence intervals (CIs). Proportions were compared with the chi-squared test. Predictors of InfraScanner detection among CT-positive cases were identified using multivariable logistic regression. Results: CT revealed a haematoma in 48 paediatric (24.00%) and 62 adult patients (31.00%). InfraScanner sensitivity was lower in children 62.50% (30/48; 95% CI 48.4–74.8) than in adults 80.65% (50/62; 95% CI 69.1–88.6; p = 0.034); specificity was higher in children 98.03% than in adults 89.86% (p = 0.003). Lesion volume greater than 3.5 mL (odds ratio [OR] 4.12; p < 0.001) and depth less than 2.5 cm (OR 3.56; p = 0.001) increased the odds of detection, whereas paediatric age reduced the odds of detection (OR 0.54; p = 0.031). Conclusion: InfraScanner shows age-differentiated diagnostic accuracy. Lower paediatric sensitivity limits stand-alone use in children. A positive result warrants immediate action. A negative result does not exclude pathology. InfraScanner is not a substitute for clinical assessment or CT.

Authors

Institutions

Publication Details

Journal
Pakistan Journal of Medical Sciences
Published
2026-11-07
DOI
https://doi.org/10.12669/pjms.42.11.21110
Primary Topic
Traumatic Brain Injury and Neurovascular Disturbances
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparative diagnostic accuracy of InfraScanner in paediatric versus adult traumatic brain injury: A prospective, computed tomography–validated study

Syed Shayan Shah, Muhammad Nawaz Khan, Muhammad Sohaib Khan
2 links
Pakistan Journal of Medical Sciences
Traumatic Brain Injury and Neurovascular Disturbances
article

Comparative diagnostic accuracy of InfraScanner in paediatric versus adult traumatic brain injury: A prospective, computed tomography–validated study

Syed Shayan Shah, Muhammad Nawaz Khan, Muhammad Sohaib Khan
article en

Abstract

Objective: To compare the diagnostic accuracy of InfraScanner against computed tomography (CT) for detection of intracranial haematoma in paediatric versus adult patients with traumatic brain injury (TBI), and to identify lesion-level predictors of device detection. Methodology: This prospective observational, CT-validated study recruited 400 consecutive TBI patients (200 paediatric, 200 adult) at the Department of Neurosurgery, Lady Reading Hospital – Medical Teaching Institution (MTI), Peshawar from January 2025 to June 2025. Blinded InfraScanner Model 2000 and CT assessments were performed within one hour of each other. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated using 95% Wilson confidence intervals (CIs). Proportions were compared with the chi-squared test. Predictors of InfraScanner detection among CT-positive cases were identified using multivariable logistic regression. Results: CT revealed a haematoma in 48 paediatric (24.00%) and 62 adult patients (31.00%). InfraScanner sensitivity was lower in children 62.50% (30/48; 95% CI 48.4–74.8) than in adults 80.65% (50/62; 95% CI 69.1–88.6; p = 0.034); specificity was higher in children 98.03% than in adults 89.86% (p = 0.003). Lesion volume greater than 3.5 mL (odds ratio [OR] 4.12; p < 0.001) and depth less than 2.5 cm (OR 3.56; p = 0.001) increased the odds of detection, whereas paediatric age reduced the odds of detection (OR 0.54; p = 0.031). Conclusion: InfraScanner shows age-differentiated diagnostic accuracy. Lower paediatric sensitivity limits stand-alone use in children. A positive result warrants immediate action. A negative result does not exclude pathology. InfraScanner is not a substitute for clinical assessment or CT.

Pakistan Journal of Medical SciencesVol. 42(11)
Lady Reading Hospital (PK)
Good health and well-being
Openalex Percentile: Top 15%
Traumatic Brain Injury and Neurovascular Disturbances
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon