Accuracy and reliability of privacy-compliant large language models for MRI protocol selection in radiological workflows

OBJECTIVE: Accurate MRI protocolling is essential for diagnostic quality and workflow efficiency, yet manual protocol selection is time-consuming and variable. This study evaluated four contemporary open-weight large language models (LLMs) for MRI protocol and optional sequence selection from real-world clinical referrals. MATERIALS AND METHODS: In this retrospective study, 1201 consecutive referral forms (mean age 58 ± 14 years; 646 men) were provided as unaltered text to each LLM, which selected an institutional protocol and optional sequences from predefined lists. A consensus of two board-certified radiologists served as reference. Performance was assessed at protocol and sequence levels using protocol accuracy and mean Jaccard index. RESULTS: Larger general-purpose models achieved the highest concordance with expert protocolling (GPT-OSS-120B: Jaccard 0.96, 95% CI: 0.96-0.97; accuracy 0.94, 0.93-0.95; Qwen-3-235B-A22B-Instruct-2507: Jaccard 0.96, 0.95-0.97; accuracy 0.94, 0.93-0.96), outperforming MedGemma-27B-Text-IT (Jaccard 0.85, 0.84-0.87; accuracy 0.79, 0.76-0.81) and Gemma-3-27B-IT (Jaccard 0.61, 0.59-0.63; accuracy 0.58, 0.55-0.60). Unacceptable protocol selections ranged from 70/1201 cases (5.8%) for GPT-OSS and 71/1201 (5.9%) for Qwen3 to 297/1201 (24.7%) for MedGemma and 820/1,201 (68.3%) for Gemma3. Among unacceptable cases, the most common error was anatomically correct but clinically suboptimal protocol selection (57.7-70.7%), followed by incorrect anatomical region (11.6-39.4%) and optional-sequence-only errors (2.8-30.2%). GPT-OSS matched expert scan duration (p = 0.18), Qwen3 was shorter (p = 0.002), and Gemma3 and MedGemma were longer (both p < 0.001). CONCLUSION: Open-weight LLMs showed high concordance with expert MRI protocolling and may support standardized protocol selection. However, clinically relevant errors persisted, underscoring the need for radiologist oversight. KEY POINTS: Question Can open-weight LLMs support accurate and standardized MRI protocol and sequence selection from clinical referrals compared with expert reference standards? Findings In 1201 referrals, LLMs achieved high concordance with expert MRI protocol selection (accuracy up to 0.94; mean Jaccard index up to 0.96), but unacceptable errors remained model-dependent and ranged from 5.8% to 68.3%. Clinical relevance Open-weight LLMs showed high agreement with expert MRI protocol decisions from clinical text and may support standardized, reliable, and scalable MRI protocolling while maintaining radiologist oversight.

Authors

Institutions

Publication Details

Journal
European Radiology
Published
2026-11-07
DOI
https://doi.org/10.1007/s00330-026-13039-9
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Accuracy and reliability of privacy-compliant large language models for MRI protocol selection in radiological workflows

Daniel L. R. Kuetting, Julian Alexander Luetkens, Dmitrij Kravchenko, Ralf Clauberg et al.
8 links
European Radiology
Artificial Intelligence in Healthcare and Education
article

Accuracy and reliability of privacy-compliant large language models for MRI protocol selection in radiological workflows

Daniel L. R. Kuetting, Julian Alexander Luetkens, Dmitrij Kravchenko, Ralf Clauberg, Sebastian Nowak, Narine Mesropyan, Zeynep Bendella, Alexander Isaak, Alexander Radbruch, Christine Kindler
article en

Abstract

OBJECTIVE: Accurate MRI protocolling is essential for diagnostic quality and workflow efficiency, yet manual protocol selection is time-consuming and variable. This study evaluated four contemporary open-weight large language models (LLMs) for MRI protocol and optional sequence selection from real-world clinical referrals. MATERIALS AND METHODS: In this retrospective study, 1201 consecutive referral forms (mean age 58 ± 14 years; 646 men) were provided as unaltered text to each LLM, which selected an institutional protocol and optional sequences from predefined lists. A consensus of two board-certified radiologists served as reference. Performance was assessed at protocol and sequence levels using protocol accuracy and mean Jaccard index. RESULTS: Larger general-purpose models achieved the highest concordance with expert protocolling (GPT-OSS-120B: Jaccard 0.96, 95% CI: 0.96-0.97; accuracy 0.94, 0.93-0.95; Qwen-3-235B-A22B-Instruct-2507: Jaccard 0.96, 0.95-0.97; accuracy 0.94, 0.93-0.96), outperforming MedGemma-27B-Text-IT (Jaccard 0.85, 0.84-0.87; accuracy 0.79, 0.76-0.81) and Gemma-3-27B-IT (Jaccard 0.61, 0.59-0.63; accuracy 0.58, 0.55-0.60). Unacceptable protocol selections ranged from 70/1201 cases (5.8%) for GPT-OSS and 71/1201 (5.9%) for Qwen3 to 297/1201 (24.7%) for MedGemma and 820/1,201 (68.3%) for Gemma3. Among unacceptable cases, the most common error was anatomically correct but clinically suboptimal protocol selection (57.7-70.7%), followed by incorrect anatomical region (11.6-39.4%) and optional-sequence-only errors (2.8-30.2%). GPT-OSS matched expert scan duration (p = 0.18), Qwen3 was shorter (p = 0.002), and Gemma3 and MedGemma were longer (both p < 0.001). CONCLUSION: Open-weight LLMs showed high concordance with expert MRI protocolling and may support standardized protocol selection. However, clinically relevant errors persisted, underscoring the need for radiologist oversight. KEY POINTS: Question Can open-weight LLMs support accurate and standardized MRI protocol and sequence selection from clinical referrals compared with expert reference standards? Findings In 1201 referrals, LLMs achieved high concordance with expert MRI protocol selection (accuracy up to 0.94; mean Jaccard index up to 0.96), but unacceptable errors remained model-dependent and ranged from 5.8% to 68.3%. Clinical relevance Open-weight LLMs showed high agreement with expert MRI protocol decisions from clinical text and may support standardized, reliable, and scalable MRI protocolling while maintaining radiologist oversight.

European Radiology
University of Bonn (DE), University Hospital Bonn (DE), German Center for Neurodegenerative Diseases (DE)
Good health and well-being
Openalex Percentile: Top 23%
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon