Parameter Identifiability and Predictive Reliability Assessment of Kinetic Models for PLGA-Based Drug Delivery Systems
Poly(lactic-co-glycolic acid) (PLGA)-based drug-delivery systems necessitate kinetic models that can not only fit well with the data but also give a stable estimation of the model parameters and a reliable prediction.In this simulation-based study, the study analyzes the ability of four models (zero-order, first-order, Higuchi, Korsmeyer–Peppas) to accurately describe a Simulatedrelease profile for PLGA under varying sampling densities and observation-noise conditions.Nonlinear least-squares fitting was used to estimate the model parameters, and practical identifiability and uncertainty and withheld-data predictive analysis were conducted.The Korsmeyer–Peppas model was best (=0.969, RMSE=0.050, MAE=0.044 and 95% prediction coverage) for the nominal C3 condition with 20 sampling points and 5% observation noise, but with a parameter CV of 18%. The first-order model achieved (=0.962), RMSE = 0.056, MAE = 0.045, and 92% coverage. Maximum value of the parameters CV was equal to 25%, 28%, 24 and 35% for the zero order, first order, Higuchi and Korsmeyer–Peppas model respectively under the most difficult C5 condition.The results demonstrate that predictive fitting is not necessarily related to good parameter identifiability.
Authors
- J. Karthika
Publication Details
- Journal
- Innovative Reviews in Engineering and Science
- Published
- 2026-11-06
- Primary Topic
- Advanced Drug Delivery Systems
- Type
- article
- Field-Weighted Citation Impact
- 0.00