A UHPLC-MS/MS method for the quantification of oxytocin in human saliva

Given the reported correlation between cerebrospinal fluid (CSF) and salivary oxytocin concentrations, salivary oxytocin has been proposed as a promising peripheral biomarker of central oxytocin activity. To date, oxytocin levels are commonly measured using enzyme immunoassays or radio-immunoassays; however, several challenges related to its accurate quantification have been reported, underscoring the need for a standardized and reliable analytical method. The present study aimed to develop and validate a liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for the quantification of oxytocin in human saliva, in accordance with EMA and FDA guidelines for bioanalytical method validation. Oxytocin levels were determined using the standard addition method. The chromatographic separation was performed through a gradient elution of two mobile phases (H 2 O + 0.1% F.A. and MeOH: DMSO 97:3 (v/v) + 0.1% F.A.) using a Phenomenex Luna Omega 1.6 μm PS C18 100 Å LC Column 50 ×2.1 mm at 40°C with a column thermostat. It was connected to a tandem mass spectrometer, and the chromatographic run lasted 5 min. Additionally, in order to evaluate precision and accuracy of the method, real-world samples from caregivers working with people with dementia were analyzed. Method validation achieved satisfactory results in terms of robustness and reproducibility, especially at higher concentration values, while expected higher variability at lower concentrations was observed. However, real-world samples analysis confirmed the applicability of the method to real biological samples. Overall, the method was able to accurately quantify oxytocin levels in real-world samples, thus demonstrating its applicability in epidemiological studies.

Authors

Institutions

Publication Details

Journal
Psychoneuroendocrinology
Published
2026-11-06
DOI
https://doi.org/10.1016/j.psyneuen.2026.108078
Primary Topic
Neuroendocrine regulation and behavior
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A UHPLC-MS/MS method for the quantification of oxytocin in human saliva

Marco Simiele, Amedeo De Nicolò, Marco Cantù, Alice Palermiti et al.
3 links
Psychoneuroendocrinology
Neuroendocrine regulation and behavior
article

A UHPLC-MS/MS method for the quantification of oxytocin in human saliva

Marco Simiele, Amedeo De Nicolò, Marco Cantù, Alice Palermiti, Jacopo Mula, Rita Pezzati, Domenico Maiese, Fabio Favata, Antonio D’Avolio, Elena Cat Genova, Sara Soloperto, Francesco Chiara, Giorgia Menegatti
article en

Abstract

Given the reported correlation between cerebrospinal fluid (CSF) and salivary oxytocin concentrations, salivary oxytocin has been proposed as a promising peripheral biomarker of central oxytocin activity. To date, oxytocin levels are commonly measured using enzyme immunoassays or radio-immunoassays; however, several challenges related to its accurate quantification have been reported, underscoring the need for a standardized and reliable analytical method. The present study aimed to develop and validate a liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for the quantification of oxytocin in human saliva, in accordance with EMA and FDA guidelines for bioanalytical method validation. Oxytocin levels were determined using the standard addition method. The chromatographic separation was performed through a gradient elution of two mobile phases (H 2 O + 0.1% F.A. and MeOH: DMSO 97:3 (v/v) + 0.1% F.A.) using a Phenomenex Luna Omega 1.6 μm PS C18 100 Å LC Column 50 ×2.1 mm at 40°C with a column thermostat. It was connected to a tandem mass spectrometer, and the chromatographic run lasted 5 min. Additionally, in order to evaluate precision and accuracy of the method, real-world samples from caregivers working with people with dementia were analyzed. Method validation achieved satisfactory results in terms of robustness and reproducibility, especially at higher concentration values, while expected higher variability at lower concentrations was observed. However, real-world samples analysis confirmed the applicability of the method to real biological samples. Overall, the method was able to accurately quantify oxytocin levels in real-world samples, thus demonstrating its applicability in epidemiological studies.

PsychoneuroendocrinologyVol. 195
University of Applied Sciences and Arts of Southern Switzerland (CH), Ente Ospedaliero Cantonale (CH), University of Turin (IT)
Good health and well-being
Openalex Percentile: Top 20%
Neuroendocrine regulation and behavior
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon