Robust synchronization of cardiac-linked biosensors under peak detection failures: a modality-agnostic approach via structural repair and Huber-IRLS regression

Abstract Cooperative sensing in clinical instruments, distributed medical devices, and body-area networks requires accurate relative timing between independently clocked sensors, such as electrocardiography (ECG) and photoplethysmography (PPG). Interval-only synchronization operates directly on inter-beat intervals and avoids waveform alignment, but conventional estimators generally assume one-to-one reference–device beat correspondence. Missed beats, motion-induced false peaks, and gross interval errors violate this assumption by creating merged or split intervals and index shifts. We propose a robust interval-only synchronization pipeline comprising: (i) Dynamic Repair of abnormally short split intervals caused by extra (false) peaks; (ii) greedy peak-failure-aware mapping with q ∈ { 1 , 2 } to represent isolated missed beats as merged intervals; and (iii) Huber-iteratively reweighted least squares regression with median absolute deviation-based residual gating. Approximate uncertainty is quantified using an OLS-style Newey–West HAC covariance estimate (approximate and conditional when gating) and Fieller confidence sets for the ratio-defined delay-dynamics parameter. Monte Carlo ablation on synthetic ECG/PPG data (ORACLE and SIGNAL pipelines) shows that structural peak-detection failures can be catastrophic for OLS (e.g. RMS E after , all ≈ 227 ms under Extra 10% and ≈ 232 ms under a mixed extreme regime). In contrast, the proposed pipeline maintains robustness; in the mixed extreme regime it achieves RMS E after , in ≈ 37.4 ms (SIGNAL) and ≈35.9 ms (ORACLE). The real-data experiment was performed as a semi-synthetic feasibility validation using matched ECG/PPG beats from a real recording, with known clock skew imposed on the PPG timestamps and controlled peak failures injected into the resulting device interval sequence.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2026-11-06
DOI
https://doi.org/10.1088/1361-6501/aeb820
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Robust synchronization of cardiac-linked biosensors under peak detection failures: a modality-agnostic approach via structural repair and Huber-IRLS regression

Khaled Ben Abdessalem
Measurement Science and Technology
Non-Invasive Vital Sign Monitoring
article

Robust synchronization of cardiac-linked biosensors under peak detection failures: a modality-agnostic approach via structural repair and Huber-IRLS regression

Khaled Ben Abdessalem
article en

Abstract

Abstract Cooperative sensing in clinical instruments, distributed medical devices, and body-area networks requires accurate relative timing between independently clocked sensors, such as electrocardiography (ECG) and photoplethysmography (PPG). Interval-only synchronization operates directly on inter-beat intervals and avoids waveform alignment, but conventional estimators generally assume one-to-one reference–device beat correspondence. Missed beats, motion-induced false peaks, and gross interval errors violate this assumption by creating merged or split intervals and index shifts. We propose a robust interval-only synchronization pipeline comprising: (i) Dynamic Repair of abnormally short split intervals caused by extra (false) peaks; (ii) greedy peak-failure-aware mapping with q ∈ { 1 , 2 } to represent isolated missed beats as merged intervals; and (iii) Huber-iteratively reweighted least squares regression with median absolute deviation-based residual gating. Approximate uncertainty is quantified using an OLS-style Newey–West HAC covariance estimate (approximate and conditional when gating) and Fieller confidence sets for the ratio-defined delay-dynamics parameter. Monte Carlo ablation on synthetic ECG/PPG data (ORACLE and SIGNAL pipelines) shows that structural peak-detection failures can be catastrophic for OLS (e.g. RMS E after , all ≈ 227 ms under Extra 10% and ≈ 232 ms under a mixed extreme regime). In contrast, the proposed pipeline maintains robustness; in the mixed extreme regime it achieves RMS E after , in ≈ 37.4 ms (SIGNAL) and ≈35.9 ms (ORACLE). The real-data experiment was performed as a semi-synthetic feasibility validation using matched ECG/PPG beats from a real recording, with known clock skew imposed on the PPG timestamps and controlled peak failures injected into the resulting device interval sequence.

Measurement Science and TechnologyVol. 37(44)
University of Kairouan (TN), Tunis El Manar University (TN)
Good health and well-being
Openalex Percentile: Top 27%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Robust synchronization of cardiac-linked biosensors under peak detection failures: a modality-agnostic approach via structural repair and Huber-IRLS regression — Khaled Ben Abdessalem · Measurement Science and Technology (2026) | TGRS Research Map | TGRS