InSafeLock endopin versus conventional distal locking screws for femoral shaft fractures: A comparative laboratory biomechanical study

The InSafeLock femoral nail is a recently developed implant that uses endopin instead of screws in its distal locking mechanism. This study aimed to compare the biomechanical features of the distal locking mechanisms of InSafeLock and conventional nails. Twenty-four artificial femoral bones were used for mechanical tests. InSafeLock nails with endopin (Group 1) and conventional nails with distal locking screws (Group 2) were inserted into the artificial bones. The biomechanical features were evaluated using axial compression and rotational performance tests. There was no statistically significant difference between Group 1 and Group 2 in the axial compression displacement tests (P = .683). No visual damage was observed on the artificial bones or intramedullary nails after axial compression fatigue tests in either group. During axial compression failure testing performed after fatigue testing, the mean failure load of Group 1 was significantly lower than that of Group 2 (1132.5 ± 15.5 N vs 11,965.5 ± 9.5 N, respectively; P = .002). Rotational performance tests showed that the torsional yield strength of the groups was not statistically different (P = .333). While the InSafeLock endopin offers ease in distal locking, it exhibits a significantly lower failure load under high axial compression forces than conventional screws.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2026-11-06
DOI
https://doi.org/10.1097/md.0000000000051478
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

InSafeLock endopin versus conventional distal locking screws for femoral shaft fractures: A comparative laboratory biomechanical study

Hakan Yurten, Seçkin Özcan, Zekeriya Ersin Çelen
Medicine
Bone fractures and treatments
article

InSafeLock endopin versus conventional distal locking screws for femoral shaft fractures: A comparative laboratory biomechanical study

Hakan Yurten, Seçkin Özcan, Zekeriya Ersin Çelen
article en

Abstract

The InSafeLock femoral nail is a recently developed implant that uses endopin instead of screws in its distal locking mechanism. This study aimed to compare the biomechanical features of the distal locking mechanisms of InSafeLock and conventional nails. Twenty-four artificial femoral bones were used for mechanical tests. InSafeLock nails with endopin (Group 1) and conventional nails with distal locking screws (Group 2) were inserted into the artificial bones. The biomechanical features were evaluated using axial compression and rotational performance tests. There was no statistically significant difference between Group 1 and Group 2 in the axial compression displacement tests (P = .683). No visual damage was observed on the artificial bones or intramedullary nails after axial compression fatigue tests in either group. During axial compression failure testing performed after fatigue testing, the mean failure load of Group 1 was significantly lower than that of Group 2 (1132.5 ± 15.5 N vs 11,965.5 ± 9.5 N, respectively; P = .002). Rotational performance tests showed that the torsional yield strength of the groups was not statistically different (P = .333). While the InSafeLock endopin offers ease in distal locking, it exhibits a significantly lower failure load under high axial compression forces than conventional screws.

MedicineVol. 105(45)
Yalova University (TR), Sağlık Bilimleri Üniversitesi (TR), Ankara Bilkent City Hospital (TR)
Good health and well-being
Openalex Percentile: Top 12%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
InSafeLock endopin versus conventional distal locking screws for femoral shaft fractures: A comparative laboratory biomechanical study — Hakan Yurten, Seçkin Özcan, et al. · Medicine (2026) | TGRS Research Map | TGRS