AI Surge Accelerates the Transition to Liquid Cooling: Rethinking Energy and Water Use in Data Center Cooling

Abstract The power density of AI workloads is rapidly driving shifts to liquid cooling. This study rethinks and assesses the global impact on energy and water demand of this cooling transformation. Results suggest that liquid cooling can reduce cooling energy use by 25-56% relative to air cooling, offering substantial energy savings for GW-scale AI data centers. Best-practice PUE values could be as low as 1.07-1.08 for today’s systems and 1.03-1.04 for emerging designs and WUE values from 0.38 to 2.63 L kWh⁻¹, depending on temperature conditions. We identify global free-cooling rack inlet temperature thresholds of 33 °C for evaporative systems and 49 °C for dry systems, demonstrating the practicality of 100% free cooling in many locations. The model finds that minimum PUEs do not necessarily coincide with minimum total energy use. Results quantify the large sustainability potential of liquid cooling and provide actionable targets for data center design and policies.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-06
DOI
https://doi.org/10.21203/rs.3.rs-10361694/v1
Primary Topic
Energy Efficiency in Computing
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

AI Surge Accelerates the Transition to Liquid Cooling: Rethinking Energy and Water Use in Data Center Cooling

Eric R. Masanet, Yingbo Zhang, Shengwei Wang
3 links
Research Square
Energy Efficiency in Computing
preprint

AI Surge Accelerates the Transition to Liquid Cooling: Rethinking Energy and Water Use in Data Center Cooling

Eric R. Masanet, Yingbo Zhang, Shengwei Wang
preprint en

Abstract

Abstract The power density of AI workloads is rapidly driving shifts to liquid cooling. This study rethinks and assesses the global impact on energy and water demand of this cooling transformation. Results suggest that liquid cooling can reduce cooling energy use by 25-56% relative to air cooling, offering substantial energy savings for GW-scale AI data centers. Best-practice PUE values could be as low as 1.07-1.08 for today’s systems and 1.03-1.04 for emerging designs and WUE values from 0.38 to 2.63 L kWh⁻¹, depending on temperature conditions. We identify global free-cooling rack inlet temperature thresholds of 33 °C for evaporative systems and 49 °C for dry systems, demonstrating the practicality of 100% free cooling in many locations. The model finds that minimum PUEs do not necessarily coincide with minimum total energy use. Results quantify the large sustainability potential of liquid cooling and provide actionable targets for data center design and policies.

Research Square
Hong Kong Polytechnic University (HK), University of California, Santa Barbara (US)
Climate action, Affordable and clean energy, Industry, innovation and infrastructure
Energy Efficiency in Computing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon