Preliminary Geotechnical Assessment Based on Dynamic Cone Penetrometer (DCP) Testing in West Lombok Housing Development Areas

The high number of residential developments along the Mataram-Gerung Bypass Road risks structural failure due to uncompacted alluvial subgrade on former agricultural land. The purpose of this study was to analyze California Bearing Ratio (CBR) and assess the subgrade bearing capacity, serving as a preliminary geotechnical assessment for residential construction planning. In-situ Dynamic Cone Penetrometer (DCP) testing was conducted at six measurement points to a depth of 1000 mm. In addition, the subsurface stratigraphic profile was characterized based on soil samples, cross-referenced with regional geological maps. The penetration value (DCPI) was then converted into a CBR percentage using Harison’s (1987) empirical correlation, while the mechanical soil parameters (qd, qu, and qall) were estimated using the Dutch Formula approach and Portland Concrete Association modification with a Safety Factor of 3. The results showed that the CBR value varied from 4.07% to 14.67%. Points B2 is categorized as Poor Subgrade (CBR 4.07%), point A2 and C2 as Medium Subgrade (CBR 6.95%–7.68%), and points A1, B1, and C1 as Good Subgrade (CBR 13.24%–14.67%). The bearing capacity estimation analysis produces dynamic penetration resistance (qd) values ​​of 216.91–574.86 kPa, ultimate bearing capacity (qu) of 64.97–151.76 kPa, and allowable bearing capacity (qall) of 21.66–50.59 kPa. Although some points have CBR in the good category, the overall qall value of the study area remains low and below the safe threshold for shallow foundations. Geotechnical recommendations include excavating and replacing topsoil with selected compacted fill material.

Authors

Institutions

Publication Details

Journal
Frontier Advances in Applied Science and Engineering
Published
2026-11-07
DOI
https://doi.org/10.59535/faase.v4i2.723
Primary Topic
Geotechnical and construction materials studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Preliminary Geotechnical Assessment Based on Dynamic Cone Penetrometer (DCP) Testing in West Lombok Housing Development Areas

Suhayat Minardi, Syamsuddin, Adella Ulyandana Jayatri, Rahmatun Inayah
1 links
Frontier Advances in Applied Science and Engineering
Geotechnical and construction materials studies
article

Preliminary Geotechnical Assessment Based on Dynamic Cone Penetrometer (DCP) Testing in West Lombok Housing Development Areas

Suhayat Minardi, Syamsuddin, Adella Ulyandana Jayatri, Rahmatun Inayah
article en

Abstract

The high number of residential developments along the Mataram-Gerung Bypass Road risks structural failure due to uncompacted alluvial subgrade on former agricultural land. The purpose of this study was to analyze California Bearing Ratio (CBR) and assess the subgrade bearing capacity, serving as a preliminary geotechnical assessment for residential construction planning. In-situ Dynamic Cone Penetrometer (DCP) testing was conducted at six measurement points to a depth of 1000 mm. In addition, the subsurface stratigraphic profile was characterized based on soil samples, cross-referenced with regional geological maps. The penetration value (DCPI) was then converted into a CBR percentage using Harison’s (1987) empirical correlation, while the mechanical soil parameters (qd, qu, and qall) were estimated using the Dutch Formula approach and Portland Concrete Association modification with a Safety Factor of 3. The results showed that the CBR value varied from 4.07% to 14.67%. Points B2 is categorized as Poor Subgrade (CBR 4.07%), point A2 and C2 as Medium Subgrade (CBR 6.95%–7.68%), and points A1, B1, and C1 as Good Subgrade (CBR 13.24%–14.67%). The bearing capacity estimation analysis produces dynamic penetration resistance (qd) values ​​of 216.91–574.86 kPa, ultimate bearing capacity (qu) of 64.97–151.76 kPa, and allowable bearing capacity (qall) of 21.66–50.59 kPa. Although some points have CBR in the good category, the overall qall value of the study area remains low and below the safe threshold for shallow foundations. Geotechnical recommendations include excavating and replacing topsoil with selected compacted fill material.

Frontier Advances in Applied Science and EngineeringVol. 4(2)
University of Mataram (ID)
Industry, innovation and infrastructure, Sustainable cities and communities
Openalex Percentile: Top 21%
Geotechnical and construction materials studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon