Deep-Learning Enhanced Augmented Reality for Robotic Radical Prostatectomy on Consumer Grade Hardware

BackgroundAugmented Reality (AR) during Robotic-Assisted Radical Prostatectomy (RARP) provides surgical guidance by overlaying patient-specific 3D Virtual Models (VM) onto the intraoperative view. A main drawback is instrument occlusion, where VM overlaps the surgical tools, disturbing the augmented view. Deep learning (DL)-based desocclusion addresses this issue, but current implementation rely on expensive, specialized hardware.MethodsWe developed an AR desocclusion pipeline running on consumer-grade hardware (∼1150 US Dollars). For model selection, we trained and benchmarked 21 encoder architectures paired with a U-Net decoder. The selected model was integrated into a macOS application using CoreML inference on the Apple Neural Engine. Memory usage, thermal state and framerate were monitored on a continuous 81-minute console session. Photon-to-photon latency (from surgical field to the surgeon eye) was measured on the DaVinci® Xi using a microcontroller-phototransistor setup.ResultsFastViT-S12/Unet offered the highest accuracy among models meeting our inference-time budget (∼2 ms inference), achieving a Dice score of 95.1% (95% CI, 94.3-95.7) internally, 91.6% (95% CI, 90.2-92.9) and 90.2% (95% CI, 84.7-94.4) on externals tests, with a mean inference time of 1.89 ± 0.36 ms. The pipeline maintained 57.98 frames per second using 1.47 GB of unified memory with a nominal thermal state. On the surgical console, photon-to-photon median latency increased from 60 ms (Q1-Q3: 57.5-62.5) to 120.5 ms (Q1-Q3: 111-131) with the AR pipeline.ConclusionsReal-time AR-RARP with DL-based desocclusion is achievable on low-cost hardware with an added latency remaining within ranges reported as technically acceptable for intraoperative use.

Authors

Institutions

Publication Details

Journal
Surgical Innovation
Published
2026-11-06
DOI
https://doi.org/10.1177/15533506261504154
Primary Topic
Augmented Reality Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Deep-Learning Enhanced Augmented Reality for Robotic Radical Prostatectomy on Consumer Grade Hardware

Hugues Turbé, Christian Lovis, Olivier Laurent Windisch, Massimo Valério et al.
1 links
Surgical Innovation
Augmented Reality Applications
article

Deep-Learning Enhanced Augmented Reality for Robotic Radical Prostatectomy on Consumer Grade Hardware

Hugues Turbé, Christian Lovis, Olivier Laurent Windisch, Massimo Valério, Mina Bjelogrlic, Diana Michele, Vincent Benard
article en

Abstract

BackgroundAugmented Reality (AR) during Robotic-Assisted Radical Prostatectomy (RARP) provides surgical guidance by overlaying patient-specific 3D Virtual Models (VM) onto the intraoperative view. A main drawback is instrument occlusion, where VM overlaps the surgical tools, disturbing the augmented view. Deep learning (DL)-based desocclusion addresses this issue, but current implementation rely on expensive, specialized hardware.MethodsWe developed an AR desocclusion pipeline running on consumer-grade hardware (∼1150 US Dollars). For model selection, we trained and benchmarked 21 encoder architectures paired with a U-Net decoder. The selected model was integrated into a macOS application using CoreML inference on the Apple Neural Engine. Memory usage, thermal state and framerate were monitored on a continuous 81-minute console session. Photon-to-photon latency (from surgical field to the surgeon eye) was measured on the DaVinci® Xi using a microcontroller-phototransistor setup.ResultsFastViT-S12/Unet offered the highest accuracy among models meeting our inference-time budget (∼2 ms inference), achieving a Dice score of 95.1% (95% CI, 94.3-95.7) internally, 91.6% (95% CI, 90.2-92.9) and 90.2% (95% CI, 84.7-94.4) on externals tests, with a mean inference time of 1.89 ± 0.36 ms. The pipeline maintained 57.98 frames per second using 1.47 GB of unified memory with a nominal thermal state. On the surgical console, photon-to-photon median latency increased from 60 ms (Q1-Q3: 57.5-62.5) to 120.5 ms (Q1-Q3: 111-131) with the AR pipeline.ConclusionsReal-time AR-RARP with DL-based desocclusion is achievable on low-cost hardware with an added latency remaining within ranges reported as technically acceptable for intraoperative use.

Surgical Innovation
University of Geneva (CH), University Hospital of Geneva (CH)
Good health and well-being
Openalex Percentile: Top 22%
Augmented Reality Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon