COMPARISON OF TRACTION FORCES IN EX VIVO VITRECTOMY USING 25+®G 20K CPM DUAL-BLADE AND 25+®G 10K CPM SINGLE-BLADE VITRECTOMY PROBES

PURPOSE: To compare vitreous traction forces generated by a 25+® gauge (G) 20,000 cuts per minute (CPM) dual-blade vitrectomy probe (HYPERVIT®) and a 25+®G 10,000 CPM single-blade vitrectomy probe (Advanced ULTRAVIT®) under flow-matched conditions. METHODS: Bovine vitreous was used in a simulated ex vivo vitrectomy model. Each probe (n=10 per type) engaged vitreous within a balanced salt solution (BSS®) chamber, while a force sensor recorded traction forces. Vacuum levels were set at 260 mmHg (dual-blade) and 340 mmHg (single-blade) to achieve flow-matching, and traction forces were measured across percentiles. RESULTS: Under flow-matched conditions, the dual-blade probe exhibited lower traction forces. Excluding forces <0.5 millinewton (mN), the 90th, 95th, and 99th percentile forces were 12.8%, 14.4%, and 14.4% lower, respectively (p<0.05). Overall mean, mean peak, and mean maximum forces were lowered by 8.01%, 15.78%, and 12.22%, respectively (p<0.05). The single-blade probe recorded traction forces of 1.60 ± 0.07 mN, 2.93 ± 0.14 mN, and 6.97 ± 0.38 mN, respectively. Whereas the dual-blade probe showed 1.47 ± 0.04 mN, 2.46 ± 0.12 mN, and 6.12 ± 0.26 mN (p<0.05). CONCLUSION: The 25+G 20K CPM dual-blade probe generated lower traction forces than the 25+G 10K CPM single-blade probe under flow-matched conditions.

Authors

Institutions

Publication Details

Journal
Retina
Published
2026-11-06
DOI
https://doi.org/10.1097/iae.0000000000005048
Primary Topic
Retinal and Macular Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

COMPARISON OF TRACTION FORCES IN EX VIVO VITRECTOMY USING 25+®G 20K CPM DUAL-BLADE AND 25+®G 10K CPM SINGLE-BLADE VITRECTOMY PROBES

Steve Charles, Brian McDonell, Ying Zhu, Vara Wuyyuru
Retina
Retinal and Macular Surgery
article

COMPARISON OF TRACTION FORCES IN EX VIVO VITRECTOMY USING 25+®G 20K CPM DUAL-BLADE AND 25+®G 10K CPM SINGLE-BLADE VITRECTOMY PROBES

Steve Charles, Brian McDonell, Ying Zhu, Vara Wuyyuru
article en

Abstract

PURPOSE: To compare vitreous traction forces generated by a 25+® gauge (G) 20,000 cuts per minute (CPM) dual-blade vitrectomy probe (HYPERVIT®) and a 25+®G 10,000 CPM single-blade vitrectomy probe (Advanced ULTRAVIT®) under flow-matched conditions. METHODS: Bovine vitreous was used in a simulated ex vivo vitrectomy model. Each probe (n=10 per type) engaged vitreous within a balanced salt solution (BSS®) chamber, while a force sensor recorded traction forces. Vacuum levels were set at 260 mmHg (dual-blade) and 340 mmHg (single-blade) to achieve flow-matching, and traction forces were measured across percentiles. RESULTS: Under flow-matched conditions, the dual-blade probe exhibited lower traction forces. Excluding forces <0.5 millinewton (mN), the 90th, 95th, and 99th percentile forces were 12.8%, 14.4%, and 14.4% lower, respectively (p<0.05). Overall mean, mean peak, and mean maximum forces were lowered by 8.01%, 15.78%, and 12.22%, respectively (p<0.05). The single-blade probe recorded traction forces of 1.60 ± 0.07 mN, 2.93 ± 0.14 mN, and 6.97 ± 0.38 mN, respectively. Whereas the dual-blade probe showed 1.47 ± 0.04 mN, 2.46 ± 0.12 mN, and 6.12 ± 0.26 mN (p<0.05). CONCLUSION: The 25+G 20K CPM dual-blade probe generated lower traction forces than the 25+G 10K CPM single-blade probe under flow-matched conditions.

Retina
Germantown Academy (US), Alcon (United States) (US), Germantown Historical Society (US)
Good health and well-being
Openalex Percentile: Top 10%
Retinal and Macular Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
COMPARISON OF TRACTION FORCES IN EX VIVO VITRECTOMY USING 25+®G 20K CPM DUAL-BLADE AND 25+®G 10K CPM SINGLE-BLADE VITRECTOMY PROBES — Steve Charles, Brian McDonell, et al. · Retina (2026) | TGRS Research Map | TGRS