Evaluation of the Physical Behavior, Biocompatibility, and Biosafety of AMCOP Elastodontic Appliances: A Prospective Observational Study

Introduction: Elastodontic appliances have become increasingly popular in interceptive orthodontics because they simultaneously address dentoalveolar discrepancies and orofacial dysfunctions while promoting physiological craniofacial growth. Their long-term clinical effectiveness, however, depends not only on treatment protocols but also on the physical stability, biocompatibility, and biosafety of the materials from which they are manufactured. Although laboratory testing and regulatory certifications provide evidence regarding material safety, limited clinical data are available concerning the behavior of these appliances after prolonged intraoral use. Objective: The present study aimed to evaluate the physical behavior, biocompatibility, and biosafety of AMCOP elastodontic appliances after six months of clinical use through a prospective observational research. Materials and Methods: Ten patients undergoing interceptive orthodontic treatment with AMCOP elastodontic appliances were prospectively monitored for six months. All participants followed an identical clinical protocol consisting of appliance wear for at least one hour during daytime and throughout the night, combined with standardized daily cleaning using liquid Marseille soap. Clinical evaluation included assessment of surface integrity, dimensional stability, maintenance of appliance morphology, elastic behavior, surface wear, permanent deformation, fractures, and overall clinical functionality. Biological outcomes included oral mucosal tolerance, allergic reactions, irritation, patient-reported comfort assessed using a Visual Analogue Scale (VAS), treatment compliance, transient hypersalivation, and overall patient satisfaction. Results: After six months, no visible dimensional changes were observed on clinical examination in any of the ten appliances. No fractures or clinically apparent structural discontinuities were detected. Minor superficial wear was observed in some appliances. Elasticity was qualitatively rated as preserved in all the appliances. No clinically apparent mucosal irritation, ulcerative lesions, or allergic reactions were recorded in any of the ten patients during follow-up. Patient comfort scores were higher at T6 compared with T0, and transient hypersalivation reported during the initial adaptation period resolved in all patients. Conclusions: Within the limitations of this prospective observational case series, the clinical findings indicate favorable appliance integrity and biological tolerance over six months of intraoral use. No clinically apparent adverse mucosal reactions were recorded. However, the qualitative nature of the physical assessments, the limited sample size, and the absence of instrumental testing do not allow definitive conclusions regarding material properties, comprehensive biocompatibility, or therapeutic effectiveness. Further studies with larger populations, longer follow-up, and objective laboratory assessments are warranted.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-11-06
DOI
https://doi.org/10.3390/ma19214717
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Evaluation of the Physical Behavior, Biocompatibility, and Biosafety of AMCOP Elastodontic Appliances: A Prospective Observational Study

Daniela Di Venere, Francesco Inchingolo, Gianna Dipalma, Filippo Cardarelli et al.
Materials
Orthodontics and Dentofacial Orthopedics
article

Evaluation of the Physical Behavior, Biocompatibility, and Biosafety of AMCOP Elastodontic Appliances: A Prospective Observational Study

Daniela Di Venere, Francesco Inchingolo, Gianna Dipalma, Filippo Cardarelli, Grazia Marinelli, Pierluigi Marotti, Francesco Magistro
article en

Abstract

Introduction: Elastodontic appliances have become increasingly popular in interceptive orthodontics because they simultaneously address dentoalveolar discrepancies and orofacial dysfunctions while promoting physiological craniofacial growth. Their long-term clinical effectiveness, however, depends not only on treatment protocols but also on the physical stability, biocompatibility, and biosafety of the materials from which they are manufactured. Although laboratory testing and regulatory certifications provide evidence regarding material safety, limited clinical data are available concerning the behavior of these appliances after prolonged intraoral use. Objective: The present study aimed to evaluate the physical behavior, biocompatibility, and biosafety of AMCOP elastodontic appliances after six months of clinical use through a prospective observational research. Materials and Methods: Ten patients undergoing interceptive orthodontic treatment with AMCOP elastodontic appliances were prospectively monitored for six months. All participants followed an identical clinical protocol consisting of appliance wear for at least one hour during daytime and throughout the night, combined with standardized daily cleaning using liquid Marseille soap. Clinical evaluation included assessment of surface integrity, dimensional stability, maintenance of appliance morphology, elastic behavior, surface wear, permanent deformation, fractures, and overall clinical functionality. Biological outcomes included oral mucosal tolerance, allergic reactions, irritation, patient-reported comfort assessed using a Visual Analogue Scale (VAS), treatment compliance, transient hypersalivation, and overall patient satisfaction. Results: After six months, no visible dimensional changes were observed on clinical examination in any of the ten appliances. No fractures or clinically apparent structural discontinuities were detected. Minor superficial wear was observed in some appliances. Elasticity was qualitatively rated as preserved in all the appliances. No clinically apparent mucosal irritation, ulcerative lesions, or allergic reactions were recorded in any of the ten patients during follow-up. Patient comfort scores were higher at T6 compared with T0, and transient hypersalivation reported during the initial adaptation period resolved in all patients. Conclusions: Within the limitations of this prospective observational case series, the clinical findings indicate favorable appliance integrity and biological tolerance over six months of intraoral use. No clinically apparent adverse mucosal reactions were recorded. However, the qualitative nature of the physical assessments, the limited sample size, and the absence of instrumental testing do not allow definitive conclusions regarding material properties, comprehensive biocompatibility, or therapeutic effectiveness. Further studies with larger populations, longer follow-up, and objective laboratory assessments are warranted.

MaterialsVol. 19(21)
University of Milan (IT), University of Perugia (IT), University of Bari Aldo Moro (IT)
Good health and well-being
Openalex Percentile: Top 11%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon