TF-Mamba: Intelligent fault diagnosis model for wind turbine bearings based on multimodal selective gating Mamba

To address the non-stationarity of wind-turbine bearing vibration signals, the need for collaborative modeling of one-dimensional sequential features and two-dimensional visual features, and the computational cost of sequence modeling, this study proposes an intelligent fault diagnosis model based on multimodal selective-gating Mamba, termed TF-Mamba. A progressive multimodal fusion framework of “feature extraction–CoSSM–explicit selection–global decision-making” is constructed. Specifically, CoSSM enables cross-modal feature interaction through shared-parameter Mamba encoding and reciprocal gating. Bi-SG performs adaptive explicit selection of fused features along the channel and spatial dimensions, and EnSSM models global sequential dependencies for final decision-making. Experiments are conducted on CWRU and the State Grid Wind-turbine Dataset (SGWD), with BMTM-Net and WCamba included as recent baselines. The main comparison yields accuracies of 99.07% and 96.85%, respectively. Across ten repeated runs, TF-Mamba achieves mean accuracies of 99.02 ± 0.05 % on CWRU and 96.75 ± 0.12 % on SGWD. Paired permutation tests against BMTM-Net give Holm-adjusted p = 0.0156 for Accuracy and Macro-F1 on both datasets. In four leave-one-load-out CWRU evaluations, its mean accuracy across the held-out loads is 97.75%, with a mean Macro-F1 of 0.9757. A separate gate-substitution comparison gives Bi-SG an SGWD mean-accuracy advantage of 0.54 percentage points over CBAM. The network contains 2.81 million parameters and has a reported single-sample inference time of 4.68 ms on an RTX 4090. These results support the diagnostic value of progressive time–frequency collaboration and selective fusion under the evaluated dataset and load conditions.

Authors

Institutions

Publication Details

Journal
Energy Reports
Published
2026-11-07
DOI
https://doi.org/10.1016/j.egyr.2026.109875
Primary Topic
Machine Fault Diagnosis Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

TF-Mamba: Intelligent fault diagnosis model for wind turbine bearings based on multimodal selective gating Mamba

Senda Zhang, Lufeng Yuan, Zhenhua Wei, Hongyu Yue et al.
1 links
Energy Reports
Machine Fault Diagnosis Techniques
article

TF-Mamba: Intelligent fault diagnosis model for wind turbine bearings based on multimodal selective gating Mamba

Senda Zhang, Lufeng Yuan, Zhenhua Wei, Hongyu Yue, Xin He, Yangang Qu
article en

Abstract

To address the non-stationarity of wind-turbine bearing vibration signals, the need for collaborative modeling of one-dimensional sequential features and two-dimensional visual features, and the computational cost of sequence modeling, this study proposes an intelligent fault diagnosis model based on multimodal selective-gating Mamba, termed TF-Mamba. A progressive multimodal fusion framework of “feature extraction–CoSSM–explicit selection–global decision-making” is constructed. Specifically, CoSSM enables cross-modal feature interaction through shared-parameter Mamba encoding and reciprocal gating. Bi-SG performs adaptive explicit selection of fused features along the channel and spatial dimensions, and EnSSM models global sequential dependencies for final decision-making. Experiments are conducted on CWRU and the State Grid Wind-turbine Dataset (SGWD), with BMTM-Net and WCamba included as recent baselines. The main comparison yields accuracies of 99.07% and 96.85%, respectively. Across ten repeated runs, TF-Mamba achieves mean accuracies of 99.02 ± 0.05 % on CWRU and 96.75 ± 0.12 % on SGWD. Paired permutation tests against BMTM-Net give Holm-adjusted p = 0.0156 for Accuracy and Macro-F1 on both datasets. In four leave-one-load-out CWRU evaluations, its mean accuracy across the held-out loads is 97.75%, with a mean Macro-F1 of 0.9757. A separate gate-substitution comparison gives Bi-SG an SGWD mean-accuracy advantage of 0.54 percentage points over CBAM. The network contains 2.81 million parameters and has a reported single-sample inference time of 4.68 ms on an RTX 4090. These results support the diagnostic value of progressive time–frequency collaboration and selective fusion under the evaluated dataset and load conditions.

Energy ReportsVol. 16
North China Electric Power University (CN), PowerChina (China) (CN)
State Grid Corporation of China
Openalex Percentile: Top 22%
Machine Fault Diagnosis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon