Application of the literature-derived modified penetration model to quantify drug particle depth in the viable epidermis post-stratum corneum transit

Purpose This study aims to determine the powdered drug penetration depth delivered by means of a micro-shock tube-based needle-free drug delivery device based on a literature-derived modified penetration model. Design/methodology/approach A two-dimensional transient compressible particle-gas flow simulation was done using ANSYS Fluent. The discrete phase model simulates drug particle behaviour in a continuous gas phase. Several pressure ratios (PRs) were used in the quantitative study. The nozzle exit pressure and particle velocity were validated against experimental results. Using modified mathematical formulae from the literature, particle or powder penetration depth, Mach number, vorticity and the effect of PRs on flow are examined to understand penetration depth changes. Findings By changing the PRs from 9 to 60, the penetration depth was investigated on the basis of particle velocity that was varied from 47 to 179 m/s obtained at different PRs. Using a modified model found in the literature, this penetration depth result has been used to examine the impact of the PRs on the penetration depth. After careful computation, the authors discovered that the penetration depth was marginally impacted between PR = 40 and 60. Penetration depth at PR = 40 and 60 was around 0.053 and 0.057 mm. Originality/value Considering the particle velocity at the stratum corneum–viable epidermis boundary, the particle penetration depth at various PRs for drug delivery using a needle-free device is crucial but rarely studied. Some helpful information for drug distribution using a needle-free device is provided by the current numerical workflow.

Authors

Institutions

Publication Details

Journal
International Journal of Numerical Methods for Heat &amp Fluid Flow
Published
2026-11-06
DOI
https://doi.org/10.1108/hff-03-2026-0400
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Application of the literature-derived modified penetration model to quantify drug particle depth in the viable epidermis post-stratum corneum transit

Ayushman Srivastava, Abhishek Kundu, Akshoy Ranjan Paul
3 links
International Journal of Numerical Methods for Heat &amp Fluid Flow
Advancements in Transdermal Drug Delivery
article

Application of the literature-derived modified penetration model to quantify drug particle depth in the viable epidermis post-stratum corneum transit

Ayushman Srivastava, Abhishek Kundu, Akshoy Ranjan Paul
article en

Abstract

Purpose This study aims to determine the powdered drug penetration depth delivered by means of a micro-shock tube-based needle-free drug delivery device based on a literature-derived modified penetration model. Design/methodology/approach A two-dimensional transient compressible particle-gas flow simulation was done using ANSYS Fluent. The discrete phase model simulates drug particle behaviour in a continuous gas phase. Several pressure ratios (PRs) were used in the quantitative study. The nozzle exit pressure and particle velocity were validated against experimental results. Using modified mathematical formulae from the literature, particle or powder penetration depth, Mach number, vorticity and the effect of PRs on flow are examined to understand penetration depth changes. Findings By changing the PRs from 9 to 60, the penetration depth was investigated on the basis of particle velocity that was varied from 47 to 179 m/s obtained at different PRs. Using a modified model found in the literature, this penetration depth result has been used to examine the impact of the PRs on the penetration depth. After careful computation, the authors discovered that the penetration depth was marginally impacted between PR = 40 and 60. Penetration depth at PR = 40 and 60 was around 0.053 and 0.057 mm. Originality/value Considering the particle velocity at the stratum corneum–viable epidermis boundary, the particle penetration depth at various PRs for drug delivery using a needle-free device is crucial but rarely studied. Some helpful information for drug distribution using a needle-free device is provided by the current numerical workflow.

International Journal of Numerical Methods for Heat &amp Fluid Flow
Motilal Nehru National Institute of Technology (IN)
Good health and well-being
Openalex Percentile: Top 17%
Advancements in Transdermal Drug Delivery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon