Large-Scale Quantification of Xenobiotics Following Non-Targeted Liquid Chromatography Tandem Mass Spectrometry

Abstract The diversity of anthropogenic organic substances in aquatic environments creates a need for analytical workflows that combine chemical coverage with reliable quantification, in order to assess global chemical pollution. Here, we present an integrated workflow that combines non-targeted and targeted liquid chromatography tandem mass spectrometry (LC-MS/MS) for the analysis of xenobiotics in river and coastal environments. We developed a web-based application, GNPS2-Quant, to convert data-dependent acquisition (DDA) results into scheduled inclusion lists for parallel reaction monitoring (PRM), using precursor m/z values and retention times, thereby accelerating the transfer from non-targeted discovery to targeted quantification within the same instrument platform. Using a quadrupole orbitrap (Exploris 480) instrument and a panel of 142 xenobiotics, we compared the quantification performance of full-scan DDA-MS1 data vs PRM. While PRM provides greater selectivity, DDA-MS1 generally provided greater sensitivity, yielding lower limits of detection for 61 compounds and lower limits of quantification for 61 compounds. Despite these differences, both methods showed comparable quantitative accuracy, with approximately 75% of quality control measurements meeting our precision criteria, which was in a similar range to measurements using multiple reaction monitoring (MRM) on a triple quadrupole mass spectrometer. Application to Southern California river and estuary samples enabled the quantification of 57 xenobiotics, with strong agreement between methods across sites. While our results highlight the utility of PRM generation from non-targeted LC-MS/MS data, our data also demonstrate that DDA-MS1 alone can provide scalable quantitative performance, avoiding costly and time-consuming reanalysis.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2026-11-06
DOI
https://doi.org/10.1021/jasms.6c00334
Primary Topic
Metabolomics and Mass Spectrometry Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Large-Scale Quantification of Xenobiotics Following Non-Targeted Liquid Chromatography Tandem Mass Spectrometry

Yourae Shin, Daniel Petras, Ansel Hsiao, Mingxun Wang et al.
3 links
Journal of the American Society for Mass Spectrometry
Metabolomics and Mass Spectrometry Studies
article

Large-Scale Quantification of Xenobiotics Following Non-Targeted Liquid Chromatography Tandem Mass Spectrometry

Yourae Shin, Daniel Petras, Ansel Hsiao, Mingxun Wang, Haiyan Ke, Maxence Derbez-Morin, T Schramm, Amancio de Souza, Thomas Cummins, Rithi Krishnaraj
article en

Abstract

Abstract The diversity of anthropogenic organic substances in aquatic environments creates a need for analytical workflows that combine chemical coverage with reliable quantification, in order to assess global chemical pollution. Here, we present an integrated workflow that combines non-targeted and targeted liquid chromatography tandem mass spectrometry (LC-MS/MS) for the analysis of xenobiotics in river and coastal environments. We developed a web-based application, GNPS2-Quant, to convert data-dependent acquisition (DDA) results into scheduled inclusion lists for parallel reaction monitoring (PRM), using precursor m/z values and retention times, thereby accelerating the transfer from non-targeted discovery to targeted quantification within the same instrument platform. Using a quadrupole orbitrap (Exploris 480) instrument and a panel of 142 xenobiotics, we compared the quantification performance of full-scan DDA-MS1 data vs PRM. While PRM provides greater selectivity, DDA-MS1 generally provided greater sensitivity, yielding lower limits of detection for 61 compounds and lower limits of quantification for 61 compounds. Despite these differences, both methods showed comparable quantitative accuracy, with approximately 75% of quality control measurements meeting our precision criteria, which was in a similar range to measurements using multiple reaction monitoring (MRM) on a triple quadrupole mass spectrometer. Application to Southern California river and estuary samples enabled the quantification of 57 xenobiotics, with strong agreement between methods across sites. While our results highlight the utility of PRM generation from non-targeted LC-MS/MS data, our data also demonstrate that DDA-MS1 alone can provide scalable quantitative performance, avoiding costly and time-consuming reanalysis.

Journal of the American Society for Mass Spectrometry
University of California System (US)
Simons Foundation
Good health and well-being
Openalex Percentile: Top 27%
Metabolomics and Mass Spectrometry Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon