Cervical lymph node image analysis using YOLO11 segmentation model: an application and performance study

OBJECTIVES: Ultrasound assessment of superficial cervical lymph nodes is clinically valuable, yet current diagnostic methods are highly operator-dependent, with limited objectivity and consistency. This study investigates a more objective approach for analyzing lymph node ultrasound images, focusing on the stability and practical applicability of different model architectures on real-world clinical data. It aims to evaluate the utility of deep learning models for detection and segmentation of superficial lymph nodes and to provide a feasible methodology for objective lymph node ultrasound analysis. METHODS: Using real-world clinical data, a cervical lymph node ultrasound image dataset comprising 1,050 patients was constructed, with histopathological confirmation and standardized clinical-imaging follow-up (≥50 % diameter reduction over 6-9 months after treatment) serving as reference standards. Three different models - transformer-based RF-DETR, two-stage YOLO11+MedSAM, and end-to-end YOLO11-Seg - were systematically compared on detection and segmentation tasks within the same dataset. RESULTS: YOLO11-Seg demonstrated superior performance in both detection and segmentation. Under COCO evaluation metrics, it achieved an mean average precision (mAP) at 0.5 of 0.795 and an mAP at 0.5:0.95 of 0.558. Pixel-level segmentation evaluation yielded a Dice coefficient of 0.775 ± 0.15 and an IoU of 0.645 ± 0.15, with Precision and Recall values of 0.796 and 0.783, respectively. In contrast, the two-stage YOLO11+MedSAM and Transformer-based models exhibited lower accuracy and reduced consistency. CONCLUSIONS: This study provides preliminary evidence for the application of deep learning-based methods in lymph node ultrasound analysis and suggests a potential technical framework for generating structured imaging data, which may support future computer-assisted assessment pending further validation.

Authors

Institutions

Publication Details

Journal
Diagnosis
Published
2026-11-06
DOI
https://doi.org/10.1515/dx-2026-0022
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Cervical lymph node image analysis using YOLO11 segmentation model: an application and performance study

Cuijuan Lou, 宣仲谦, Yamin Li, Cancan Zhang et al.
4 links
Diagnosis
Medical Image Segmentation Techniques
article

Cervical lymph node image analysis using YOLO11 segmentation model: an application and performance study

Cuijuan Lou, 宣仲谦, Yamin Li, Cancan Zhang, Hongxia Wu, Xuanbai Yu, Yunyun Bai, Ruiting Wang
article en

Abstract

OBJECTIVES: Ultrasound assessment of superficial cervical lymph nodes is clinically valuable, yet current diagnostic methods are highly operator-dependent, with limited objectivity and consistency. This study investigates a more objective approach for analyzing lymph node ultrasound images, focusing on the stability and practical applicability of different model architectures on real-world clinical data. It aims to evaluate the utility of deep learning models for detection and segmentation of superficial lymph nodes and to provide a feasible methodology for objective lymph node ultrasound analysis. METHODS: Using real-world clinical data, a cervical lymph node ultrasound image dataset comprising 1,050 patients was constructed, with histopathological confirmation and standardized clinical-imaging follow-up (≥50 % diameter reduction over 6-9 months after treatment) serving as reference standards. Three different models - transformer-based RF-DETR, two-stage YOLO11+MedSAM, and end-to-end YOLO11-Seg - were systematically compared on detection and segmentation tasks within the same dataset. RESULTS: YOLO11-Seg demonstrated superior performance in both detection and segmentation. Under COCO evaluation metrics, it achieved an mean average precision (mAP) at 0.5 of 0.795 and an mAP at 0.5:0.95 of 0.558. Pixel-level segmentation evaluation yielded a Dice coefficient of 0.775 ± 0.15 and an IoU of 0.645 ± 0.15, with Precision and Recall values of 0.796 and 0.783, respectively. In contrast, the two-stage YOLO11+MedSAM and Transformer-based models exhibited lower accuracy and reduced consistency. CONCLUSIONS: This study provides preliminary evidence for the application of deep learning-based methods in lymph node ultrasound analysis and suggests a potential technical framework for generating structured imaging data, which may support future computer-assisted assessment pending further validation.

Diagnosis
Zhejiang Normal University (CN), Fuyang City People's Hospital (CN)
Good health and well-being
Openalex Percentile: Top 22%
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon