Selective Correction of Condition-Sensitive Parameters for Cross-Condition Torque Prediction in an EMG-Driven Elbow Musculoskeletal Model

Electromyography-driven musculoskeletal models estimate muscle forces and joint torque. A shared parameter set can leave errors that vary with movement speed and load. This study examined selective condition correction in an EMG-driven elbow model. The model retained a common parameter set and added speed- and load-dependent terms only to selected parameters. Ten healthy participants performed constrained isokinetic elbow flexion-extension. Subject-specific MuJoCo models were constructed from OpenSim arm26. Speed-Load had the lowest mean validation RMSE among three calibration combinations (1.37 N·m) and was used for common calibration. Length-range constraints were included during fitting. Full reduced mean RMSE by 10.0-18.6% across held-out repetitions, interpolation and extrapolation conditions. The largest reduction occurred in extrapolation: RMSE decreased from 2.08 to 1.70 N·m, while mean R² increased from 0.71 to 0.81. The ablation models had intermediate mean errors. The full two-stage procedure improved within-subject torque prediction across the tested speed and target-torque conditions with a limited number of additional coefficients.

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2026-11-06
DOI
https://doi.org/10.1088/1873-4030/aebecf
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Selective Correction of Condition-Sensitive Parameters for Cross-Condition Torque Prediction in an EMG-Driven Elbow Musculoskeletal Model

Xingzhao Guo, Jie Wang, Jianshe Gao, Xiaobo Rao et al.
Medical Engineering & Physics
Muscle activation and electromyography studies
article

Selective Correction of Condition-Sensitive Parameters for Cross-Condition Torque Prediction in an EMG-Driven Elbow Musculoskeletal Model

Xingzhao Guo, Jie Wang, Jianshe Gao, Xiaobo Rao, qiang liu, Yu Wang
article en

Abstract

Electromyography-driven musculoskeletal models estimate muscle forces and joint torque. A shared parameter set can leave errors that vary with movement speed and load. This study examined selective condition correction in an EMG-driven elbow model. The model retained a common parameter set and added speed- and load-dependent terms only to selected parameters. Ten healthy participants performed constrained isokinetic elbow flexion-extension. Subject-specific MuJoCo models were constructed from OpenSim arm26. Speed-Load had the lowest mean validation RMSE among three calibration combinations (1.37 N·m) and was used for common calibration. Length-range constraints were included during fitting. Full reduced mean RMSE by 10.0-18.6% across held-out repetitions, interpolation and extrapolation conditions. The largest reduction occurred in extrapolation: RMSE decreased from 2.08 to 1.70 N·m, while mean R² increased from 0.71 to 0.81. The ablation models had intermediate mean errors. The full two-stage procedure improved within-subject torque prediction across the tested speed and target-torque conditions with a limited number of additional coefficients.

Medical Engineering & Physics
Zhengzhou University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Henan Province
Good health and well-being
Openalex Percentile: Top 27%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Selective Correction of Condition-Sensitive Parameters for Cross-Condition Torque Prediction in an EMG-Driven Elbow Musculoskeletal Model — Xingzhao Guo, Jie Wang, et al. · Medical Engineering & Physics (2026) | TGRS Research Map | TGRS