When the RotaWire Crosses but Cannot Advance: Dual‐Lumen Microcatheter–Assisted RotaWire Delivery
RotaWire delivery can be challenging in severely calcified device-uncrossable coronary lesions when conventional wire exchange through a microcatheter is not feasible. We report a 76-year-old man with a severely calcified mid-left anterior descending coronary artery (LAD) lesion in which neither a microcatheter nor a 0.75 mm balloon could cross. A second channel was created using a penetration wire through a dual-lumen microcatheter, allowing direct RotaWire crossing. However, the RotaWire could not be advanced sufficiently into the distal LAD. After intentional proximal pullback of the dual-lumen microcatheter, the microcatheter and RotaWire were held together and advanced as a single unit, enabling adequate distal RotaWire positioning and successful rotational atherectomy. This case highlights a distinct challenge after successful direct RotaWire crossing and demonstrates coupled advancement with a dual-lumen microcatheter as a potential bailout technique when distal RotaWire advancement remains difficult.
Authors
- Masanobu Ishii (ORCID: https://orcid.org/0000-0003-4137-9136)
- Kazumasa Kurogi (ORCID: https://orcid.org/0000-0001-7889-7143)
- Kenichi Tsujita (ORCID: https://orcid.org/0000-0002-4314-259X)
- Nobuyasu Yamamoto (ORCID: https://orcid.org/0000-0002-7763-6539)
Institutions
- Miyazaki Prefectural NOBEOKA Hospital (JP)
- Kumamoto University (JP)
Publication Details
- Journal
- Catheterization and Cardiovascular Interventions
- Published
- 2026-11-06
- DOI
- https://doi.org/10.1002/ccd.70998
- Primary Topic
- Coronary Interventions and Diagnostics
- Type
- article
- Field-Weighted Citation Impact
- 0.00