Safety and efficacy of endovascular treatment of wide-neck intracranial aneurysms: comparison between stent-assisted coiling and intrasaccular flow disruption with the contour device

PURPOSE: To investigate the association between endovascular treatment strategy and the occurrence of postprocedural DWI lesions and periprocedural complications as well as retreatment rates in patients undergoing elective endovascular treatment (EVT) for unruptured wide-neck intracranial aneurysms. METHODS: This retrospective single-center study includes all consecutive patients who underwent elective EVT with stent-assisted coiling (SAC) or Contour device (CD) of unruptured wide-neck intracranial aneurysms between January 2019 and January 2026. Wide-neck aneurysms were defined as aneurysms with a neck ≥4 mm and/or a dome-to-neck ratio < 2. Postprocedural MRI was assessed for new DWI lesions. Uni- and multivariable regression analysis was performed to identify predictors for the primary outcome variables DWI lesions and periprocedural complications. Secondary outcome variables included procedure time, residual perfusion and retreatment rates. RESULTS: A total of 96 patients (50% SAC, 50% CD) were included. Postprocedural DWI lesions were detected in 60% of patients overall with a significant difference between the two groups (78% SAC vs. 43% CD; p<0.001). Periprocedural complications (SAC 13% vs. CD 13%; p = 1.0) and retreatment rates (SAC 7% vs. CD 6%; p = 0.754) did not differ between the two groups. In a multivariate regression analysis, SAC (aOR 4.15, 95% CI 1.39-12.4, p = 0.011) was an independent predictor of postprocedural DWI lesions. CONCLUSION: In elective EVT of unruptured wide-neck intracranial aneurysms, stent-assisted coiling was associated with a significantly higher rate of postprocedural DWI lesions compared to the Contour device. Periprocedural complications and retreatment rates were similar between the treatment strategies.

Authors

Institutions

Publication Details

Journal
Neuroradiology
Published
2026-11-06
DOI
https://doi.org/10.1007/s00234-026-04262-8
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Safety and efficacy of endovascular treatment of wide-neck intracranial aneurysms: comparison between stent-assisted coiling and intrasaccular flow disruption with the contour device

Christian J. Thaler, Maxim Bester, Christian Heitkamp, Helge C. Kniep et al.
3 links
Neuroradiology
Intracranial Aneurysms: Treatment and Complications
article

Safety and efficacy of endovascular treatment of wide-neck intracranial aneurysms: comparison between stent-assisted coiling and intrasaccular flow disruption with the contour device

Christian J. Thaler, Maxim Bester, Christian Heitkamp, Helge C. Kniep, Lukas Meyer, Felix Schlicht, Laurens Winkelmeier, Matthias Bechstein, Jens Fiehler, Vincent Geest, Bogdana Tokareva, Luca Meucci, Gregor Peter
article en

Abstract

PURPOSE: To investigate the association between endovascular treatment strategy and the occurrence of postprocedural DWI lesions and periprocedural complications as well as retreatment rates in patients undergoing elective endovascular treatment (EVT) for unruptured wide-neck intracranial aneurysms. METHODS: This retrospective single-center study includes all consecutive patients who underwent elective EVT with stent-assisted coiling (SAC) or Contour device (CD) of unruptured wide-neck intracranial aneurysms between January 2019 and January 2026. Wide-neck aneurysms were defined as aneurysms with a neck ≥4 mm and/or a dome-to-neck ratio < 2. Postprocedural MRI was assessed for new DWI lesions. Uni- and multivariable regression analysis was performed to identify predictors for the primary outcome variables DWI lesions and periprocedural complications. Secondary outcome variables included procedure time, residual perfusion and retreatment rates. RESULTS: A total of 96 patients (50% SAC, 50% CD) were included. Postprocedural DWI lesions were detected in 60% of patients overall with a significant difference between the two groups (78% SAC vs. 43% CD; p<0.001). Periprocedural complications (SAC 13% vs. CD 13%; p = 1.0) and retreatment rates (SAC 7% vs. CD 6%; p = 0.754) did not differ between the two groups. In a multivariate regression analysis, SAC (aOR 4.15, 95% CI 1.39-12.4, p = 0.011) was an independent predictor of postprocedural DWI lesions. CONCLUSION: In elective EVT of unruptured wide-neck intracranial aneurysms, stent-assisted coiling was associated with a significantly higher rate of postprocedural DWI lesions compared to the Contour device. Periprocedural complications and retreatment rates were similar between the treatment strategies.

Neuroradiology
University Medical Center Hamburg-Eppendorf (DE)
Good health and well-being
Openalex Percentile: Top 15%
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon