A Semi‐automatic Puncture System for Liver Rupture Haemostasis: Ex Vivo and In Vivo Study

BACKGROUND: Liver rupture caused by blunt trauma can result in severe haemorrhage and death. Percutaneous puncture embolisation is a potential minimally invasive approach for haemostasis, but manual puncture is limited by difficult bleeding-site localization and hand-eye coordination. METHODS: We developed a semi-automatic puncture system integrating a robotic arm and a compact rack-pinion driven end-effector. Positioning and posture accuracy were evaluated, followed by ex vivo and in vivo porcine liver embolisation experiments. RESULTS: The system can achieve mean positioning and posture accuracies of 0.36 mm and 1.03° under load-free conditions, and 1.83 mm and 2.67° in the soft-tissue phantom, respectively. Embolic material was delivered to the target region, and cessation of visible bleeding was observed within approximately 20 s in the ex vivo and in vivo experiments. CONCLUSIONS: The results support the preliminary feasibility of this approach for percutaneous puncture embolisation of complex hepatic lacerations.

Authors

Institutions

Publication Details

Journal
International Journal of Medical Robotics and Computer Assisted Surgery
Published
2026-11-06
DOI
https://doi.org/10.1002/rcs.70248
Primary Topic
Abdominal Trauma and Injuries
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Semi‐automatic Puncture System for Liver Rupture Haemostasis: Ex Vivo and In Vivo Study

Ziqi Zhou, Baoliang Zhao, Pak Kin Wong, Liang Yao et al.
5 links
International Journal of Medical Robotics and Computer Assisted Surgery
Abdominal Trauma and Injuries
article

A Semi‐automatic Puncture System for Liver Rupture Haemostasis: Ex Vivo and In Vivo Study

Ziqi Zhou, Baoliang Zhao, Pak Kin Wong, Liang Yao, Peixuan Ge, Peng Zhang, Tao Zhang, Jinhang Li, Yunpeng Ji, Ying Hu
article en

Abstract

BACKGROUND: Liver rupture caused by blunt trauma can result in severe haemorrhage and death. Percutaneous puncture embolisation is a potential minimally invasive approach for haemostasis, but manual puncture is limited by difficult bleeding-site localization and hand-eye coordination. METHODS: We developed a semi-automatic puncture system integrating a robotic arm and a compact rack-pinion driven end-effector. Positioning and posture accuracy were evaluated, followed by ex vivo and in vivo porcine liver embolisation experiments. RESULTS: The system can achieve mean positioning and posture accuracies of 0.36 mm and 1.03° under load-free conditions, and 1.83 mm and 2.67° in the soft-tissue phantom, respectively. Embolic material was delivered to the target region, and cessation of visible bleeding was observed within approximately 20 s in the ex vivo and in vivo experiments. CONCLUSIONS: The results support the preliminary feasibility of this approach for percutaneous puncture embolisation of complex hepatic lacerations.

International Journal of Medical Robotics and Computer Assisted SurgeryVol. 22(6)
Tianjin University (CN), Chinese Academy of Sciences (CN), University of Macau (MO), Harbin Institute of Technology (CN), Southern University of Science and Technology (CN), Shenzhen Institutes of Advanced Technology (CN)
Good health and well-being
Openalex Percentile: Top 12%
Abdominal Trauma and Injuries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon