Effect of Mechanical Loading and Simulated Aging on the Microleakage of Metal-Reinforced and Experimental Glass Ionomer Cements

Marginal microleakage is commonly used as an in vitro indicator of restorative materials' sealing performance, although it does not directly predict clinical longevity. Glass-ionomer cements (GICs) chemically interact with tooth mineral and are used where adhesion and fluoride release are advantageous. This study compared dye penetration around a metal-reinforced GIC (Hi-Dense) and an experimental high powder-to-liquid ratio GIC (EXPT), before and after mechanical load cycling. We received 80 freshly extracted, non-carious human molars, prepared Class II, and restored with one of the two GICs. For each material, specimens were allocated to an unloaded control or to load cycling intended to represent one day, one week, or one month. Specimens were coated with nail varnish except for a 1-mm perimeter around the restoration, immersed in 0.1% neutral red for 24 h at 37°C, sectioned, and examined at ×15 magnification. Dye penetration was scored separately at cervical and occlusal margins. Group comparisons were analysed using the Mann–Whitney test with a 95% confidence level. Dye penetration was generally limited, and no section received a score greater than 2. At the occlusal margin after one month of cycling, EXPT showed greater leakage than Hi-Dense (reported p ≤ 0.002). At cervical margins, EXPT showed greater penetration than Hi-Dense at the reported one-day (p ≤ 0.002) and one-month (p ≤ 0.03) loading periods. No significant material difference was reported in unloaded specimens. The authors reported no major overall influence of cycling duration on leakage patterns, although occlusal leakage in Hi-Dense was lower after the one-month condition. Under the conditions of this in vitro experiment, the metal-reinforced Hi-Dense material exhibited less dye penetration than EXPT at both margins, particularly under selected loading conditions. These findings support a comparative laboratory advantage for Hi-Dense, but clinical effectiveness cannot be inferred from dye penetration alone.

Authors

Publication Details

Journal
Attahadi Medical Journal
Published
2026-11-06
DOI
https://doi.org/10.69667/amj.26413
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Effect of Mechanical Loading and Simulated Aging on the Microleakage of Metal-Reinforced and Experimental Glass Ionomer Cements

Mohamed Abour
Attahadi Medical Journal
Dental materials and restorations
article

Effect of Mechanical Loading and Simulated Aging on the Microleakage of Metal-Reinforced and Experimental Glass Ionomer Cements

Mohamed Abour
article en

Abstract

Marginal microleakage is commonly used as an in vitro indicator of restorative materials' sealing performance, although it does not directly predict clinical longevity. Glass-ionomer cements (GICs) chemically interact with tooth mineral and are used where adhesion and fluoride release are advantageous. This study compared dye penetration around a metal-reinforced GIC (Hi-Dense) and an experimental high powder-to-liquid ratio GIC (EXPT), before and after mechanical load cycling. We received 80 freshly extracted, non-carious human molars, prepared Class II, and restored with one of the two GICs. For each material, specimens were allocated to an unloaded control or to load cycling intended to represent one day, one week, or one month. Specimens were coated with nail varnish except for a 1-mm perimeter around the restoration, immersed in 0.1% neutral red for 24 h at 37°C, sectioned, and examined at ×15 magnification. Dye penetration was scored separately at cervical and occlusal margins. Group comparisons were analysed using the Mann–Whitney test with a 95% confidence level. Dye penetration was generally limited, and no section received a score greater than 2. At the occlusal margin after one month of cycling, EXPT showed greater leakage than Hi-Dense (reported p ≤ 0.002). At cervical margins, EXPT showed greater penetration than Hi-Dense at the reported one-day (p ≤ 0.002) and one-month (p ≤ 0.03) loading periods. No significant material difference was reported in unloaded specimens. The authors reported no major overall influence of cycling duration on leakage patterns, although occlusal leakage in Hi-Dense was lower after the one-month condition. Under the conditions of this in vitro experiment, the metal-reinforced Hi-Dense material exhibited less dye penetration than EXPT at both margins, particularly under selected loading conditions. These findings support a comparative laboratory advantage for Hi-Dense, but clinical effectiveness cannot be inferred from dye penetration alone.

Attahadi Medical Journal
Good health and well-being
Openalex Percentile: Top 11%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon