The use of Electromagnetic Suspensions in Improving the Dosing Efficiency of Powders
Localized powder feeding requires a controllable flow even for fine or agglomeration-prone materials. This paper presents a vibratory feeder in which magnetic granules are excited by an alternating electromagnetic field and agitate powder near the feeding path. The study reports operating observations across magnetic-granule counts, experimental flow-rate curves versus magnetic induction for WC, Al₂O₃, TiN, and Bro-10, and ten gravimetric measurements for each of six powder materials in a separate repeatability series at one fixed magnetic-field setting and 50 Hz. The six-material results are summarized by their arithmetic mean, sample standard deviation, and coefficient of variation. The measurements characterize prototype operation and repeatability; they do not establish absolute dosing error or a validated theoretical flow law.
Authors
- Pavel Topală (ORCID: https://orcid.org/0000-0003-3779-4564)
- Eugeniu Ungureanu (ORCID: https://orcid.org/0009-0003-0821-7108)
Institutions
- Alecu Russo State University of Bălți (MD)
- Universitatea Națională de Știință și Tehnologie Politehnica București (RO)
Publication Details
- Journal
- Global Journal of Researches in Engineering
- Published
- 2026-11-06
- DOI
- https://doi.org/10.34257/gjrea278188
- Primary Topic
- Granular flow and fluidized beds
- Type
- article
- Field-Weighted Citation Impact
- 0.00