An antibody-functionalized N-CQD-based “Off–On” fluorescent probe for serum C3M detection: a proof-of-concept study toward postoperative joint rehabilitation assessment
by Bland-Altman analysis. In a pilot proof-of-concept study with 9 participants (4 healthy controls and 5 patients), C3M levels were significantly elevated in patients, with distinct temporal profiles at postoperative days 1, 3, 7, and 14. This sensitive and simple assay provides a promising approach for serum C3M detection and may be potentially adaptable to point-of-care testing in the future, although the current method still requires laboratory fluorescence instrumentation and a 40-min incubation. However, the small sample size precludes any conclusion regarding rehabilitation assessment; larger studies with standardized rehabilitation endpoints are required.