SnS-modified platinum electrode for electrocatalytic hydrazine oxidation: mechanistic insights and electrochemical sensing

) of 0.30-0.32. Differential pulse voltammetry enabled HZ determination over two linear concentration ranges of 5-35 µM and 50-3500 µM, with a limit of detection of 2.68 µM and a limit of quantification of 8.13 µM. The sensor further exhibited good operational stability, reproducibility, selectivity against common interfering species, and satisfactory recoveries of 81.0-99.3% for simulated industrial water samples. These results demonstrate that the Pt/SnS-modified electrode is a prospective electrochemical sensing platform for HZ detection, while the mechanistic electrochemical studies provide fundamental insight into its potent electrocatalytic performance.

Authors

Institutions

Publication Details

Journal
RSC Advances
Published
2026-11-18
DOI
https://doi.org/10.1039/d6ra06914b
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

SnS-modified platinum electrode for electrocatalytic hydrazine oxidation: mechanistic insights and electrochemical sensing

Jahir Ahmed, Mohammad A. Hasnat, Jari S. Algethami, Farid A. Harraz et al.
RSC Advances
Electrochemical sensors and biosensors
article

SnS-modified platinum electrode for electrocatalytic hydrazine oxidation: mechanistic insights and electrochemical sensing

Jahir Ahmed, Mohammad A. Hasnat, Jari S. Algethami, Farid A. Harraz, Md. Mahmudul Hasan, Mohd Faisal, Mohammad Imran Hossain, Md. Tarikul Islam, Md Musfiqur Rahman, S. M. Maksudur Rahman Shanto
article en

Abstract

) of 0.30-0.32. Differential pulse voltammetry enabled HZ determination over two linear concentration ranges of 5-35 µM and 50-3500 µM, with a limit of detection of 2.68 µM and a limit of quantification of 8.13 µM. The sensor further exhibited good operational stability, reproducibility, selectivity against common interfering species, and satisfactory recoveries of 81.0-99.3% for simulated industrial water samples. These results demonstrate that the Pt/SnS-modified electrode is a prospective electrochemical sensing platform for HZ detection, while the mechanistic electrochemical studies provide fundamental insight into its potent electrocatalytic performance.

RSC AdvancesVol. 16(50)
Shahjalal University of Science and Technology (BD), Waseda University (JP), Iowa State University (US), Najran University (SA)
Najran University, Shahjalal University of Science and Technology
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon