Effect of Carbon-Fiber Negative Air Ionization (NAI) on Air Sampled in a Pediatric Hospital: Culturable Airborne Bacteria, Species Diversity, and Biofilm Formation

Bioaerosols in hospital air pose a threat of respiratory infections, particularly among immunocompromised patients. Abating their effects by diverse methods proposed for air purification remains an open topic. In particular, low environmental bioaerosol concentrations, alongside species diversity, make such studies more difficult. We designed environmental indoor air samplers aimed at: (i) direct collection and quantification of culturable airborne bacteria from a selected location and (ii) accurate evaluation of effects of negative air ions (NAIs) on airborne bacteria. We studied ion–bioaerosol interaction in three distinct pediatric hospital departments by collecting non-treated (NTAS) and ion-treated (ITAS) samples side by side. Air was sampled at 0.5 m/s for 90 min (68.7 m3), with airborne bacteria collected directly onto chromogenic media. NTASs were dominated by Micrococcus luteus (58.27%), Staphylococcus hominis (15.56%), and S. haemolyticus (10.37%). ITASs were dominated by M. luteus (38.73%), S. haemolyticus (20.42%), S. hominis (12.68%), and S. warneri (11.27%). Overall, bacterial counts were 1.37–6.13-fold higher in NTASs than in ITASs across isolated species, indicating a substantial reduction in culturable airborne bacteria following NAI treatment. These findings show the promise of carbon-fiber-based NAI technology as a complementary approach to improving hospital air quality and reducing airborne bacterial contamination.

Authors

Institutions

Publication Details

Journal
Microorganisms
Published
2026-11-06
DOI
https://doi.org/10.3390/microorganisms14112560
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Effect of Carbon-Fiber Negative Air Ionization (NAI) on Air Sampled in a Pediatric Hospital: Culturable Airborne Bacteria, Species Diversity, and Biofilm Formation

Predrag Kolarž, Stefan Mijatović, Aleksandar Sovtić, Jelena Antić‐Stanković et al.
3 links
Microorganisms
Indoor Air Quality and Microbial Exposure
article

Effect of Carbon-Fiber Negative Air Ionization (NAI) on Air Sampled in a Pediatric Hospital: Culturable Airborne Bacteria, Species Diversity, and Biofilm Formation

Predrag Kolarž, Stefan Mijatović, Aleksandar Sovtić, Jelena Antić‐Stanković, Irena Arandjelović, Borko Gobeljić, Mihail Baša, Andjelija Ž. Ilić, Milos B. Kuzmanovic, Jelena Trajković
article en

Abstract

Bioaerosols in hospital air pose a threat of respiratory infections, particularly among immunocompromised patients. Abating their effects by diverse methods proposed for air purification remains an open topic. In particular, low environmental bioaerosol concentrations, alongside species diversity, make such studies more difficult. We designed environmental indoor air samplers aimed at: (i) direct collection and quantification of culturable airborne bacteria from a selected location and (ii) accurate evaluation of effects of negative air ions (NAIs) on airborne bacteria. We studied ion–bioaerosol interaction in three distinct pediatric hospital departments by collecting non-treated (NTAS) and ion-treated (ITAS) samples side by side. Air was sampled at 0.5 m/s for 90 min (68.7 m3), with airborne bacteria collected directly onto chromogenic media. NTASs were dominated by Micrococcus luteus (58.27%), Staphylococcus hominis (15.56%), and S. haemolyticus (10.37%). ITASs were dominated by M. luteus (38.73%), S. haemolyticus (20.42%), S. hominis (12.68%), and S. warneri (11.27%). Overall, bacterial counts were 1.37–6.13-fold higher in NTASs than in ITASs across isolated species, indicating a substantial reduction in culturable airborne bacteria following NAI treatment. These findings show the promise of carbon-fiber-based NAI technology as a complementary approach to improving hospital air quality and reducing airborne bacterial contamination.

MicroorganismsVol. 14(11)
University of Belgrade (RS), Institut za zdravstvenu zaštitu majke i deteta Srbije "Dr Vukan Čupić" (RS), Institute of Physics Belgrade (RS)
Good health and well-being
Openalex Percentile: Top 20%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon