Predicting Hypotension after Spinal Anesthesia for Elective Cesarean Delivery Using a Multimodal Ultrasound Approach: A Prospective Observational Study

Background: Spinal anesthesia-induced hypotension (SAIH) is common during cesarean delivery, and clinical predictors perform poorly. Aims and Objective: To evaluate the inferior vena cava collapsibility index (IVCCI), subclavian vein collapsibility index (SCVCI) and left ventricular end-diastolic area (LVEDA), alone and combined, for predicting SAIH. Materials and Methods: This prospective observational study enrolled 100 consecutive term parturients (ASA II) undergoing elective cesarean delivery under spinal anesthesia at a tertiary centre in Jhansi (May 2025–April 2026). IVCCI, SCVCI and LVEDA were measured before the block. SAIH was defined as a systolic blood pressure fall >20% from baseline or <90 mmHg within 30 minutes. Sensitivity, specificity, predictive values and receiver operating characteristic curves were analysed. Results: SAIH occurred in 64 parturients (64%; 95% CI 54.2–72.7). IVCCI values did not overlap between groups (area under the curve [AUC] 1.00, 95% CI 0.96–1.00); at the ≥40% cut-off, sensitivity was 90.6% and specificity 100%. SCVCI ≥21% had a sensitivity of 93.8% and specificity of 61.1% (AUC 0.81); LVEDA did not discriminate (AUC 0.46). A multimodal rule (IVCCI ≥40% or SCVCI ≥21%) increased sensitivity to 98.4% (p=0.06 vs IVCCI alone) and negative predictive value to 95.7%, but reduced specificity (61.1%) and accuracy (85% vs 94%). Hypotensive parturients had a higher baseline heart rate (100.5 vs 85.3 bpm; p<0.001). Conclusion: IVCCI showed excellent apparent discrimination for SAIH in this single-centre cohort. Adding SCVCI increased sensitivity but reduced specificity and accuracy, and LVEDA added no predictive information. These thresholds require independent validation.

Authors

Publication Details

Journal
International Journal of Medical Sciences and Academic Research
Published
2026-11-05
DOI
https://doi.org/10.5281/zenodo.23978540
Primary Topic
Anesthesia and Pain Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Predicting Hypotension after Spinal Anesthesia for Elective Cesarean Delivery Using a Multimodal Ultrasound Approach: A Prospective Observational Study

Roopesh Kumar, Chitrangana Gupta, Rajat Kumar, Anshul Jain
International Journal of Medical Sciences and Academic Research
Anesthesia and Pain Management
article

Predicting Hypotension after Spinal Anesthesia for Elective Cesarean Delivery Using a Multimodal Ultrasound Approach: A Prospective Observational Study

Roopesh Kumar, Chitrangana Gupta, Rajat Kumar, Anshul Jain
article en

Abstract

Background: Spinal anesthesia-induced hypotension (SAIH) is common during cesarean delivery, and clinical predictors perform poorly. Aims and Objective: To evaluate the inferior vena cava collapsibility index (IVCCI), subclavian vein collapsibility index (SCVCI) and left ventricular end-diastolic area (LVEDA), alone and combined, for predicting SAIH. Materials and Methods: This prospective observational study enrolled 100 consecutive term parturients (ASA II) undergoing elective cesarean delivery under spinal anesthesia at a tertiary centre in Jhansi (May 2025–April 2026). IVCCI, SCVCI and LVEDA were measured before the block. SAIH was defined as a systolic blood pressure fall >20% from baseline or <90 mmHg within 30 minutes. Sensitivity, specificity, predictive values and receiver operating characteristic curves were analysed. Results: SAIH occurred in 64 parturients (64%; 95% CI 54.2–72.7). IVCCI values did not overlap between groups (area under the curve [AUC] 1.00, 95% CI 0.96–1.00); at the ≥40% cut-off, sensitivity was 90.6% and specificity 100%. SCVCI ≥21% had a sensitivity of 93.8% and specificity of 61.1% (AUC 0.81); LVEDA did not discriminate (AUC 0.46). A multimodal rule (IVCCI ≥40% or SCVCI ≥21%) increased sensitivity to 98.4% (p=0.06 vs IVCCI alone) and negative predictive value to 95.7%, but reduced specificity (61.1%) and accuracy (85% vs 94%). Hypotensive parturients had a higher baseline heart rate (100.5 vs 85.3 bpm; p<0.001). Conclusion: IVCCI showed excellent apparent discrimination for SAIH in this single-centre cohort. Adding SCVCI increased sensitivity but reduced specificity and accuracy, and LVEDA added no predictive information. These thresholds require independent validation.

International Journal of Medical Sciences and Academic Research
Openalex Percentile: Top 9%
Anesthesia and Pain Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon