Conformal prediction under cross-period exchangeability breakdown: a causal-admissibility M&V cascade for LNG receiving terminals

Liquefied natural gas (LNG) receiving terminals require measurement and verification baselines that support energy-performance assessment under the IPMVP and ISO 50006 frameworks. Post-hoc interpretability methods explain a fitted model but do not themselves document an independent pre-fit input review. This paper develops a six-stage cascade with a separate pre-fit review. A pre-prediction causal admissibility screening audit decides admissibility from the raw data alone and emits a log that an external verifier regenerates without any trained-model checkpoint; causal discovery then restricts the forecaster’s pooling readout to the recovered ancestors, a Gaussian-process residual model with weighted-block conformal calibration supplies the prediction intervals, and a topology-weighted scorer ranks process nodes for non-routine-event hypotheses. On a 180 d LNG simulation the cascade attains strong point-prediction accuracy on specified reporting subsets and 3/3 conditional top-3 candidate coverage under an explicit limited-power caveat. Its central finding is negative: under the short calibration window, conformal coverage collapses across periods, a cross-period exchangeability breakdown traced to a nonconformity-score distribution shift. The tested naive adaptive-conformal repairs restore coverage only by suppressing acute faults, whereas a recency-weighted non-exchangeable variant escapes that trade-off under chronological online replay. A paired post-fit residual calibration then brings the reporting row within the study’s point-accuracy targets without reopening the admissibility decision. A supplementary test on 90 independent fault/healthy pairs reveals residual false alarms and rankings identical to a constant reference. Three recommendations follow: a baseline covering relevant operating and seasonal conditions, an independent admissibility audit log reproducible without the trained model, and direct-state supervisory control and data acquisition templates at each major processing node.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2026-11-23
DOI
https://doi.org/10.1088/1361-6501/aebdbc
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Conformal prediction under cross-period exchangeability breakdown: a causal-admissibility M&V cascade for LNG receiving terminals

Shanqi Zhou, Xin Song, Daofang Chang
6 links
Measurement Science and Technology
Fault Detection and Control Systems
article

Conformal prediction under cross-period exchangeability breakdown: a causal-admissibility M&V cascade for LNG receiving terminals

Shanqi Zhou, Xin Song, Daofang Chang
article en

Abstract

Liquefied natural gas (LNG) receiving terminals require measurement and verification baselines that support energy-performance assessment under the IPMVP and ISO 50006 frameworks. Post-hoc interpretability methods explain a fitted model but do not themselves document an independent pre-fit input review. This paper develops a six-stage cascade with a separate pre-fit review. A pre-prediction causal admissibility screening audit decides admissibility from the raw data alone and emits a log that an external verifier regenerates without any trained-model checkpoint; causal discovery then restricts the forecaster’s pooling readout to the recovered ancestors, a Gaussian-process residual model with weighted-block conformal calibration supplies the prediction intervals, and a topology-weighted scorer ranks process nodes for non-routine-event hypotheses. On a 180 d LNG simulation the cascade attains strong point-prediction accuracy on specified reporting subsets and 3/3 conditional top-3 candidate coverage under an explicit limited-power caveat. Its central finding is negative: under the short calibration window, conformal coverage collapses across periods, a cross-period exchangeability breakdown traced to a nonconformity-score distribution shift. The tested naive adaptive-conformal repairs restore coverage only by suppressing acute faults, whereas a recency-weighted non-exchangeable variant escapes that trade-off under chronological online replay. A paired post-fit residual calibration then brings the reporting row within the study’s point-accuracy targets without reopening the admissibility decision. A supplementary test on 90 independent fault/healthy pairs reveals residual false alarms and rankings identical to a constant reference. Three recommendations follow: a baseline covering relevant operating and seasonal conditions, an independent admissibility audit log reproducible without the trained model, and direct-state supervisory control and data acquisition templates at each major processing node.

Measurement Science and TechnologyVol. 37(47)
Software Engineering Institute of Guangzhou (CN), Shanghai Maritime University (CN)
Ministry of Industry and Information Technology of the People's Republic of China
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon